Battery Charging Set-points (@ 25°C)
[multiply voltages by (2) for 24 volt systems]
DIP
Absorp.
Float
Equalize
Switch
Battery
Stage
Stage
Stage
Settings
Type
(volts)
(volts)
(volts)
4-5-6
off-off-off 1 - Sealed*
14.00
13.50
off-off-on 2 - Sealed*
14.15
13.50
14.40
off-on-off 3 - Sealed*
14.30
13.50
14.60
off-on-on 4- AGM/Flooded
14.40
13.50
15.10
on-off-off 5 - Flooded
14.60
13.50
15.30
on-off-on 6 - Flooded
14.70
13.50
15.40
on-on-off 7 - L-16
15.40
13.40
16.00
on-on-on
8 - Custom
Custom
Custom
Custom
* "Sealed" battery type includes gel and AGM batteries
Current Compensation:
12 Volt systems
24 Volt systems
Compensated set-points
Compensation threshold
Load and Solar Control
(multiply voltages by (2) for 24 volt
:
systems)
Default values (customizable)
LVD / USB charging
LVR
Instant LVD
HVD - solar
HVD - load / USB charging
HVDR - solar
HVDR - load USB charging
LVD Warning
LVD Override
Maximum # LVD overrides
(not customizable)
42
Technical Specifications
:
Absorp.
Equalize
Equalize
Equalize
Equalize
Equalize
Equalize
Equalize
Time
Time
Timeout
Interval
LVD
LVR
Interval
Interval
(volts)
(volts)
(mins)
(mins)
(mins)
(days)
(days)
(days)
150
11.50
12.60
150
60
120
28
11.30
12.80
150
60
120
28
13.00
11.50
180
120
180
28
11.70
13.20
180
120
180
28
11.90
13.40
180
180
240
28
12.10
13.60
180
180
240
14
12.30
13.80
Custom
Custom
Custom
Custom
Custom
Custom Custom
Custom
Custom
-15 mV / A
-30 mV / A
LVD
3A
See table above
See table above
10.0V
Current stage set-point
+ 0.5V (@ 25ºC)
15.3V
13.8V (@ 25ºC)
14.5V
10 minutes
10 minutes
No limit unless
V_batt < Instant LVD
Lighting Control (DIP 1 ON):
Lighting Timer Setting
Lighting Test Timer
Data & Communications:
Data Port (future use)
Datalogging (future use)
Comm. Protocol
Digital Meter:
Resolution
Viewing Area
Display Color
Backlight
Operating Temperature
Storage Temperature
Environmental:
Maximum Operating Altitude
Operating Temperature
Storage Temperature
Humidity
Tropicalization
Protections
Power-up against any active faults
Reverse Polarity - battery and array
Solar Short-Circuit
Solar High Voltage Disconnect
High Heatsink Temperature - Current De-rating
High Heatsink Temperature - Load Disconnect
Load Short-Circuit
Load Over-Current
Heatsink Temperature Limit
RTS Terminals
EcoBoost MPPT Operator's Manual
Dusk-Dawn (default)
5 minutes
USB Micro-B
30-day maximum
Serial
128 x 64
70mm x 40mm
blue on white
LED
-20ºC to +60ºC
-30ºC to +80ºC
2000 meters
-40ºC to +60ºC
-40ºC to +80ºC
100% n.c.
Conformally coated PCBs;
Marine-rated terminals
43