Function
RS485B alt
RS485/422 RX(B)
RS485A alt
RS485/422 RX(A)
RS485/RS422 TX(B)
RS485/RS422 TX(A)
Important
The recommended maximum cable length is 30 m (98 ft).

Operating conditions

Product
Temperature
AXIS P1367-E
-40 °C to 55 °C
(-40 °F to 131 °F)
Maximum temperature (intermittent):
60 °C (140 °F)

Power consumption

NO
NO TICE
NO
TICE
TICE
Use a limited power source (LPS) with either a rated output power limited to ≤100W
or a rated output current limited to ≤5A.
Product
AXIS P1367-E
AXIS P1367-E Network Camera
Pin
Notes
1
RX pair for all modes (combined RX/TX for 2-wire RS485)
2
3
TX pair for RS422 and 4-wire RS485
4
Power over Ethernet (PoE)
IEEE 802.3af/802.3at Type
1 Class 3
Max. 9.2 W
Typical 5.3 W
29
Humidity
10–100% RH (condensing)