Operating conditions

This Axis product is intended for indoor and outdoor use.
Temperature
Normal: -50 °C to 55 °C (-58 °F to 131 °F)
Maximum (intermittent): 65 °C (149 °F)
Cold start: -40 °C to 55 °C (-40 °F to 131 °F)

Power consumption

Typical consumption
16 W
Important
When using the 22 m (72 ft) AXIS Cable 24 V DC/24–240 V AC with
AXIS Q8685-E 24 V AC/DC, a power supply capable of delivering 400 W is required to
compensate for the power loss in the cable.
NO TICE
TICE
NO
NO
TICE
The typical power consumption values are based on the following:
• Any losses in the power cable disregarded
• No positioning active
• No wiper motor active
• Temperature at 25 °C / 77 °F (all heaters off)
• One H.264 stream at maximum resolution
• MJPEG stream recorded to SD card
AXIS Q8685-E PTZ Network Camera
Humidity
10–100% RH (non-condensing)
Max consumption
204 W