CROUSE-HINDS
Betriebsanleitung
Operating instructions
SERIES
Mode d'emploi
Explosionsgeschützte Steckvorrichtungen
32 A, 4-polig, 5-polig, GHG 517
Explosion protected plug and socket system
32 A, 4-pole, 5-pole, GHG 517
Fiches et prises de 32 A, à 4 pôles, 5 pôles,
pour atmosphères explosives, GHG 517
GHG 510 7002 P0002 D/GB/F (h)

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Eaton GHG 517

  • Seite 1 Operating instructions SERIES Mode d’emploi Explosionsgeschützte Steckvorrichtungen 32 A, 4-polig, 5-polig, GHG 517 Explosion protected plug and socket system 32 A, 4-pole, 5-pole, GHG 517 Fiches et prises de 32 A, à 4 pôles, 5 pôles, pour atmosphères explosives, GHG 517...
  • Seite 2: Inhaltsverzeichnis

    1 Technical data ......... 7 1 Caractéristiques techniques ....11 1.1 Steckvorrichtung GHG 517 ....3 1.1 Plug and socket GHG 517 ...... 7 1.1 Fiches et prises GHG 517 .....11 2 Sicherheitshinweise ......4 2 Safety instructions ......... 8 2 Consignes de sécurité...
  • Seite 3: Maßbild

    Explosionsgeschützte Steckvorrichtung 32 A, GHG 517 Technische Angaben Maßbilder in mm X = Befestigungsmaße 1.1 Steckvorrichtung GHG 517 Kodierung Zone 2 Gerätekennzeichnung nach 2014/34/EU: D II 3 G Ex nC IIC T6 / T5 Baumusterprüfbescheinigung: PTB 99 ATEX 1115 Wandsteckdose...
  • Seite 4: Sicherheitshinweise

    Die Steckvorrichtungen sind auch im „normalen digtem und einwandfreiem Zustand zu Industriebereich“ verwendbar. betreiben. Die Steckvorrichtungen für Niederspannungen GHG 517 sind mit einem Lastschalter ausge- Reparaturen, die den Explosionsschutz stattet und sind bis max. 32 A einsetzbar betreffen, dürfen nur von COOPER CROUSE- Flanschsteckdose 5-polig (siehe technische Daten).
  • Seite 5: Installation

    Explosionsgeschützte Steckvorrichtung 32 A, GHG 517 Nach einem Kurzschluss im Stromkreis ist Öffnen des Gerätes / Bild 1 die Funktionsfähigkeit der Steckvorrichtung Elektrischer Anschluss und der Stecker zu überprüfen. Der elektrische Anschluss des Betriebsmittels darf nur durch Elektrofachpersonal in Anleh- Da die Schaltkontakte wegen der druck- nung an EN/IEC 60079-14 erfolgen.
  • Seite 6: Stecker/Kupplung

    Explosionsgeschützte Steckvorrichtung 32 A, GHG 517 Der Betreiber muss dafür sorgen, dass beim Beim Einsatz von KLE mit einer niedrigeren GHG 517, 4-polig 50/60Hz Betrieb der Steckvorrichtung überall ein als der für das Gerät zutreffenden IP-Schutzart, gleiches Erdpotential anliegt. (siehe Seite 3, technische Daten) wird die IP-Schutzart des gesamten Gerätes reduziert.
  • Seite 7: Dimensional Drawings

    Explosion protected plug and socket system 32 A, GHG 517 Technical data Dimensions in mm X = fixing dimensions 1.1 Plug and socket GHG 517 Code Zone 2 Marking acc. to 2014/34/EU: D II 3 G Ex nC IIC T6 / T5...
  • Seite 8: Safety Instructions

    Explosion protected plug and socket system 32 A, GHG 517 Safety instructions In case of use in an extremely aggressive Dimensions in mm atmosphere, you can obtain information X = fixing dimensions Operations must be carried out concerning the chemical resistance of the...
  • Seite 9: Installation

    Explosion protected plug and socket system 32 A, GHG 517 After a short in the circuit, the functioning of The insulation of the conductors shall reach Fig. 1 the plug and socket system and of the plugs up to the terminal. The conductor itself shall has to be checked.
  • Seite 10: Plug/Coupler

    Explosion protected plug and socket system 32 A, GHG 517 GHG 517, 4-pole 50/60Hz When using cable entries with a lower IP The user must ensure that a uniform equipoten- protection than that which applies to the device tial earth applies throughout when the plug and (see page 7 , technical data), the IP protection of socket system is operated.
  • Seite 11: Plans Cotés

    Fiches et prises de 32 A pour atmosphères explosives, GHG 517 Caractéristiques techniques Dimensions en mm X = dimensions de fixation 1.1 Fiche et prise GHG 517 Codage Zone 2 Marquage selon 2014/34/UE: D II 3 G Ex nC IIC T6 / T5 Attestation d’exame de type:...
  • Seite 12: Consignes De Sécurité

    - acier spécial AISI 316 qu’avec le consentement par écrit de la part de COOPER CROUSE-HINDS / CEAG. Les fiches et prises du type GHG 517 pour Lors de l’exploitation, les instructions selon atmosphère explosive ne sont pas point 7 de ce mode d’emploi doivent être appropriées à...
  • Seite 13: Installation

    Fiches et prises de 32 A pour atmosphères explosives, GHG 517 Seul l’utilisateur est responsable de l’emploi Ouverture du dispositif/ Fig. 1 comme prévu de cette fiche et prise, en Raccordement électrique tenant compte des conditions générales Le raccordement électrique du dispositif ne doit existant dans l’établissement...
  • Seite 14: Fiche / Prolongateur

    à ce que des garnitures convenables Des réparations ne doivent être exécutées qu’à pour le diamètre du câble soient employées. GHG 517 , 4 pôles 50/60 Hz l’aide de pièces de rechange d’origine COOPER Après le montage du câble, la collerette de fixation (page 13, pos.
  • Seite 15 Notizen / Notes / Remarques...
  • Seite 16 Cooper Crouse-Hinds GmbH functionality. Their use in whatever form is subject to prior approval Neuer Weg-Nord 49 by Eaton. The same applies to Trademarks (especially Eaton, Moeller, 69412 Eberbach and Cutler-Hammer). The Terms and Conditions of Eaton apply, as E-Mail: Info-Ex@Eaton.com referenced on Eaton Internet pages and Eaton order confirmations.