1. DESCRIPTION.
1.1 HELMET: is composed of a fibre shell covered with 3 coats of paint, the last one of
which, the most external one, is polyurethane; a polycarbonate visor;
for KOMPAT88 and PROF88 series a reinforced and padded plastic device is supplied
for weight balance on the operator's shoulders; a polyamide collar which closes
efficiently and comfortably round the operator's neck; a head-band adjustable from 53
to 63 cm (6-5/8 to 7-7/8 hat size).
1.2 BLOWER UNITS: They are composed of an ABS case with socket and ON/OFF
switch; a fan unit actuated by an electric micro motor and an electronic air flow
indicator with alarm for the T8X and T8X-IS systems.
1.3
HOSE ASSEMBLY:
1.3.1 For respirators with K80 - K80E helmets: it consists of a spiraled hose enclosed by
smooth plastic for easy decontamination.
1.3.2 For respirators with K80S helmets: it consists of a corrugated hose with fittings for
helmet-blower unit connection.
1.4 BATTERY ASSEMBLIES:
1.4.1-LI 300 and LI-870: the pack consists of rechargeable lithium batteries in a sealed ABS
housing with non reversible plug; a circuit protection against short-circuits and over-
discharge.
1.4.2 NM300 / 8 battery ass.y (built into T9R blower): It is composed of 8 NI-MH batteries
connected in series.
1.4.3 PROF88 and KOMPAT88 battery ass.y: consists of 9 rechargeable NI-CD batteries
connected in series and, ALTERNATIVELY, for PROF88-LI and KOMPAT88-LI, 3
rechargeable lithium batteries connected in series.
1.5 FILTERS
1.5.1 ZP3 FILTER: The letter "R" marked on the filter shows that the dust filter or filtering
part of a combined filter can be used for more than one working shift after exposure to
aerosols; the letters "NR" indicate that the use is strictly limited to one working shift.
The filter is made of micro porous technical paper finely pleated with normalized EN
148-1 thread ( see filter use instruction).
1.5.2 ZA2P3 FILTER: it is made of 2 parts - the first of finely pleated submicron technical
paper and the other of activated carbon.
Connection: Thread - meets EN 148-1 standard requirements (see use instructions)
1.6
AIRFLOW INDICATORS:
1.6.1 ELECTRONIC INDICATOR - with audible alarm : mounted on the T8X / T8X-IS
blower units for the powered respirators with K80E helmets.
1.6.2 SPHERE TYPE INDICATOR : for the powered respirators with K80 and K80S
helmets.
1.7
MD1 MANUAL EMERGENCY DEVICE: composed of a plastic pump with non return
valve.
2.TECHNICAL FEATURES
2.1
NOISE LEVEL: < 75 dB.
2.2
SPECIFICATIONS:
0313212-L4
K80E T8X-L4
160
0313212-L8
K80E T8X-L8
160
0313214-L4
K80S T8-L4
120
0313214-L8
K80S T8-L8
120
0313215
K80S T9
120
0313218-L4
K80 T8-L4
120
0313218-L8
K80 T8-L8
120
0313219
K80S T9R
120
0313220
K80E T8X-IS
120
0313216
PROF88
120
0313216-LI
PROF88-LI
120
0313217
KOMPAT88
160
0313217-LI
KOMPAT88-LI
160
ISTRUZIONI D'USO – USE INSTRUCTIONS –
GEBRAUCHSANLEITUNG – MODE D'EMPLOI -
INSTRUCCIONES PARA EL USO - Οδηγίες Χρήσης-Instruções
ENGLISH
Lithium
7,4
800
3000 mAh
Lithium
7,4
800
8700 mAh
Lithium
7,4
1000
3000 mAh
Lithium
1000
7,4
8700 mAh
600
12
N.A
Lithium
7,4
1000
3000 mAh
Lithium
7,4
1000
8700 mAh
> 0,15
12
NM 300/8
600
Lithium
800
7,4
8700 mAh
NI-CD
10,8
600
2200 mAh
Lithium
11,1
600
2600 mAh
NI-CD
10,8
600
2200 mAh
Lithium
600
11,1
2600 mAh
para o uso
3.

OPERATION

3.1
The blower unit, powered by rechargeable battery, takes in air through the filters and
sends it, via hose, to the inside of the helmet. The helmet goes into slight positive
over pressure and the wearer breathes filtered air only. Expired air is expelled
through the diaphragm valves.
3.2 Manual device operation(possible only with MD1 device): use MD1 device only to
leave the contaminated area in case of respirator dysfunction. Do not use during
normal working operation. Release the fasteners near the valves and while holding
the rigid plastic support, pump air.
4.
USE
4.1
For respiratory protection against solid and liquid aerosols if fitted with ZP3 particle
filters.
For respiratory protection against particles, and organic vapours gas and organic
vapors, mist and solid and liquid aerosols if fitted with ZA2P3 combined filters.
The powered respirators are designed for the protection of the respiratory tract of the
wearer and not for other risks such as the protection of the face or eyes.
a)Some uses for which the powered respirators for the protection of the respiratory system
against solid and liquid aerosols (ZP3
• Cutting, grinding and sanding of any type:
based
paint, marble and stone in
• Powder coating, insulation
plasma cutting,
• mining and
Gardening,
b)against solid and liquid aerosols, organic gases and vapors (with ZA2P3 filters):
• Mixing / spraying of pesticides, fungicides, herbicides.
• Handling slurry.
• Waste Management.
• Cutting, grinding and sanding of any type - wood, metal, painted surfaces including lead
based paint, marble and stone in general, fiberglass, carbon and glass fibers.
• Powder coating, insulation work, bagging, woodworking, demolition, brazing, cutting and
plasma cutting, metal polishing.
• Extractions and excavations, foundries, cement works, renovations, paving operations.
• Gardening, grain handling, animal feed, farming and animal husbandry.
4.2 LIMITATIONS
a) Do not use in atmospheres immediately dangerous to life or health.
b) Do not use against gas and vapors if the respirator is fitted only with dust filters.
c) Do not wear for protection against gases, vapours, carbon monoxide, natural gas and
fumigants.
d) Do not use for protection against fire smoke.
e) Do not use in closed environments (tanks, silos etc.).
f) Do not use in atmospheres containing less than 17% oxygen.
g) Do not use in explosive atmospheres.
h) Do not use for protection against harmful dust where the concentration in the atmosphere
exceeds 500 times the TLV (UNI10720)
i) Do not use in environments with concentrations lower than 500 times the TLV when said
concentrations produce situations immediately dangerous to life and health.
5.
USE INSTRUCTIONS
5.1
BATTERY CHARGING:
5.1.1 LI-300 e LI-870 BATTERIES:
2 years or
>4
Charging of the rechargeable Lithium battery must be done exclusively with the
300 cycles
KASCO LI-02 battery charger (see use instructions packed with the respirator).
Recharge time: LI-300 – about 4 hours ; LI-870 – about 11 hours
2 years or
>8
RECHARGE THE BATTERY AFTER EACH USE.
300 cycles
5.1.2 LITHIUM BATTERIES 3S1P:
2 years or
Charging of rechargeable lithium batteries 3S1P must be carried out with Kasco LI-
>4
300 cycles
3S1 charger only (see instructions).
Recharge time: 3 hours
2 years or
5.1.3 NM-300/8 BATTERY:
>8
300 cycles
The built-in battery can be recharged with the KASCO Z15/220 battery charger .
The built-in battery recharge can be done in the following ways:
2 years or
N.A
a) with blower Off and tractor not running (about 14 hours to charge)
300 cycles
b) with tractor running and blower unit switched either ON or OFF indifferently
c) with Z15/220 battery charger and blower unit in the OFF position
2 years or
>4
Recharge time: about 14 hours
300 cycles
STORE THE BATTERIES ALMOST COMPLETELY DISCHARGED WITH BLOWER
UNIT SWITCHED OFF AND THE CORD UNPLUGGED FROM THE BLOWER.
2 years or
>8
5.1.4 NC 220/9 BATTERY:
300 cycles
The recharge of the 9 NI-CD batteries connected in series must be done with KASCO
NC9 chargers ( see use instructions packed with the respirator).
2 years or
300 cycles
Recharge time: about 6 hours.
IF THE NI-CD BATTERIES DO NOT SUPPLY THE DECLARED CAPACITY, REPEAT
2 years or
THE CHARGE-DISCHARGE CYCLE 5 TIMES AS FAST AS POSSIBLE IN ORDER
>8
300 cycles
TO OBTAIN MAXIMUM CAPACITY PERFORMANCE.
STORE BATTERIES ALMOST COMPLETELY DISCHARGED WITH THE HELMET
2 years or
>4
300 cycles
SWITCHED OFF.
2 years or
>4
5.2 PREPARING THE RESPIRATOR:
300 cycles
5.2.1 T8 / T8X / T8X-IS BLOWER UNITS:
a)
Slip the belt through the battery and blower hook .
2 years or
>4
300 cycles
b)
Connect the battery to the blower with the cord and screw tight to make contact.
c)
Make sure that the unit is ON and running properly.
d)
Make sure that the filter gasket is properly inserted into the filter housing.
2 years or
>4
300 cycles
e)
Before using the filter for the first time check the expiry date to make sure the filters
have not expired; make sure that seals have not been broken and that the filters are
the correct ones for the respirator model in use.
Rev. N. 2 del 10/07/2018
filter)
are designed
wood, metal, painted surfaces
general, fiberglass,
work, bagging, woodworking, demolition, brazing, cutting,
metal
polishing.
excavations, foundries,
cement
works, renovations,
grain
handling, animal feed,
farming and animal
IST-USO-0906004
IDP203
Pag.6 di 23
including
lead
glass
fiber,
carbon fiber.
paving
operations.
husbandry.