Symptom
problem
Motor does
Machine does
not start.
not function.
Motor makes
Machine does
a humming
not function.
sound, but
does not run.
Motor stops
Machine does
automatically.
not function.
Poor suction.
Machine does
not function
properly.
Vibrations in
Machine not
the machine.
steady.
8

SpaRE paRTS

The following spare parts are available for the product (refer to
the exploded view, Fig. IV on page 39.
article number
Description
TEV-385
0000100600
Fan wheel TEV-385
0000100604
Motor TEV-385; 230-400V/3ph/50Hz
TEV-585
0000100601
Fan wheel TEV-585
0000100605
Motor TEV-585; 230-400V/3ph/50Hz
0000100437/010812/0 TEV-RANGE
possible cause
Solution
No mains
Check the mains
voltage.
voltage.
Mains cord
Repair or replace
defective.
mains cord.
Loose contacts.
Repair the
contacts.
Motor protection
Replace the
switch defective.
motor protection
switch.
Motor defective.
Repair or replace
motor.
Motor uses 2
Repair the phase
phases instead of
connection.
3 (three-phase
motor only).
Motor capacitor
Repair or replace
defective/not
the motor
connected (single
capacitor.
phase motor
only).
Motor protection
Let the machine
switch activated.
cool down for
some time.
Check setting of
motor protection
switch (MPS)
according to
electrical
diagram.
Motor defective.
Repair or replace
the motor.
Inverted
Change the
direction of
direction of
rotation of the
rotation.
motor (three-
phase motor
only).
Motor defective.
Repair or replace
the motor.
Extraction fan
Clean the
polluted.
extraction fan.
Outside air is
Check or replace
being extracted.
the sealing
material.
Imbalance in the
Clean the
extraction fan.
extraction fan.
article number
Description
TEV-765
0000100602
Fan wheel TEV-765
0000100606
Motor TEV-765; 230-400V/3ph/50Hz
TEV-985
0000100603
Fan wheel TEV-985
0000100607
Motor TEV-985; 230-400V/3ph/50Hz
9

ELEcTRicaL DiagRaM

Refer to the separately supplied electrical diagram.
10

DiSpOSaL

After life of the product, dispose it of in accordance with
federal, state or local regulations.

cE DEcLaRaTiON

CE declaration of conformity for machinery
We, Plymovent Manufacturing BV, Wezelkoog 11, 1822 BL
Alkmaar, the Netherlands, herewith declare, on our own
responsibility, that the product(s):
- TEV-385
- TEV-585
- TEV-765
- TEV-985
which this declaration refers to, are in accordance with the
conditions of the following Directive:
- Machine Directive 2006/42 EC
- EMC directive 2004/108 EC
- LVD 2006/95/EC
- ErP directive 2009/125/EC
Alkmaar, the Netherlands, 1 December 2012
Ir. F. Coehoorn
Vice President Research & Development
An installation is defined as a combination of several finished
products or components that are assembled by an installer at
a given place. The various parts of the installation are intended
to operate together in a particular environment and to perform
a specific task. The entire installation must comply with the
relevant directives and standards. The assembly instructions
given by the manufacturer, as well as the whole method of
installation, must be in accordance with good engineering
practices within the context of installations, as well as
installation rules. Considering the above, the installer will be
responsible for completing the installation and issuing the final
CE Declaration of Conformity.
EN - 7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tev-765Tev-585Tev-985

Inhaltsverzeichnis