Follow the instructions of paragraph "DIRECT CONNECTION" related to the modes of connection to
the electrical grid.To operate the product through recessed switches, it is necessary that , during
operation, the switches on the product are always turned on 1, as shown in the image (Y).
To turn the product on via wall switch, connect a bipolar switch in series to the "L" and "N"
extremities, as shown in the image (a).
The connections should be implemented as follows:
To control the speed by means of a recessed switch, connect the two terminals of the switch to the
"S1" and "S2" extremities, as illustrated.
It is also possible to switch the wall ON / OFF commands and select speed remotely.
Follow the instructions of paragraph "DIRECT CONNECTION" related to the modes of connection to
the electrical grid. SOLO turns off when it's disconnected with the main system. When it's
reconnected it takes the speed which was set before (I or II).

3.4 POWER SUPPLY CONNECTION

Before proceeding with connection, make sure that the power supply cables (line and neutral) are
present in the area specially formed in the wall.
89
ADVANCED
Extract the particular internal wall mounting (4i) and the tools
necessary for connecting the power supply network with the
stripped wires provided in the special compartment.