Signalling
AL 8
-In the work stage the stove detects a
pressure below the vacuum switch setting
NO NEG
threshold.
PRESS
-The system is stopped.
AL 9
-Appears when the combustion air flow is
INSUFF
below a certain threshold.
DRAUGHT
AL E
-Occurs when the water pressure does not
come within the values for correct
WATER
operation.
PRESSURE
-The system is stopped.
-Occurs in case of cutting in heating
AL A
chamber water temperature safety
thermostat.
SAFETY H2O
-The system is stopped.
AL B
-Occurs when the gearmotor works
AUG TRIAC
continuously and for more than 60 sec.
-The system is stopped.
ERROR
-Occurs in case of water T detection probe
Al C
fault,
WATER PROBE
displaying T H2O = 0 °C.
- The shutdown procedure
S1
is activated.
AL F
-Occurs when the water temperature has
HOT
exceeded the fixed limits.
-The system is stopped.
WATER S1
-Occurs in case of water T detection probe
Al G
fault,
WATER PROBE
displaying T H2O = 0 °C.
- The shutdown procedure
S2
is activated.
AL I
-Occurs when the water temperature has
HOT
exceeded the fixed limits.
-The system is stopped.
WATER S2
-Occurs in case of water T detection probe
Al H
fault,
WATER PROBE
displaying T H2O = 0 °C.
- The shutdown procedure
S3
is activated.
AL d
-Occurs when the water temperature has
HOT
exceeded the fixed limits.
-The system is stopped.
WATER S3
AWAITING
-Occurs on relighting the stove immediately
after having shut it down.
COOL
AIRFLOW
-Occurs when the air flow meter is
METER
disconnected.
FAILURE
-Occurs when the water temperature falls
FROST RISK
below a certain value.
-Occurs when the stove has exceeded
SERVICE
1800 hours of operation or 2000 Kg pellet,
since the previous servicing.
DUE
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
Fault
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are open-stuck.
-Faulty vacuum switch.
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are open-stuck.
-Faulty air flow meter.
-Occurs when the pressure transducer on
the water circuit detects a pressure below
or above the fixed limits.
-The safety thermostat has detected a
temperature above the setting threshold
due to overheating of the heating chamber
water blocking gearmotor operation.
-The controller detects a faulty gearmotor
control relay (contacts stuck).
-Faulty probe
-The probe is disconnected from the board.
-Occurs when the temperature probe in the
heating chamber detects a value above
92°C.
-Faulty probe
-The probe is disconnected from the board.
-Occurs when the temperature probe in the
heating chamber detects a value above
92°C.
-Faulty probe
-The probe is disconnected from the board.
-Occurs when the temperature probe in the
heating chamber detects a value above
92°C.
-Reset attempt in shutdown stage with
stove hot in cooling stage.
-The controller does not detect the amount
of combustion air and does not shut down
the stove; it only excludes the air flow
meter functions.
-The stove controller detects the water
temperature below 6°C and displays a
message.
-Extraordinary maintenance notice.
Possible causes
59
Cures
-Check cleanness of the fume duct and
combustion chamber.
-Check hermetic closing of the door.
-Check closing of the overpressure valves.
-Other reinstatement operations must be
carried out by a service centre.
-Check cleanness of the fume duct and
combustion chamber.
-Check hermetic closing of the door.
-Check closing of the overpressure valves.
-Other reinstatement operations must be
carried out by a service centre.
-Check the cause of the problem, restoring
the circuit pressure by bringing it to the
normal operating value.
-Check the cause of excessive overheating.
-Reset the relevant safety thermostat by
pressing the reset button.
-Reinstatement operations must be carried
out by a service centre.
-Reinstatement operations must be carried
out by a service centre.
-Check the cause of the problem, restoring
the temperature by bringing it to the normal
operating value.
-Reinstatement operations must be carried
out by a service centre.
-Check the cause of the problem, restoring
the temperature by bringing it to the normal
operating value.
-Reinstatement operations must be carried
out by a service centre.
-Check the cause of the problem, restoring
the temperature by bringing it to the normal
operating value.
-Alarm reset is possible only after
shutdown.
-Reinstatement operations must be carried
out by a service centre.
-The pump starts in order to move the water
inside the heating circuit.
- Monitor the water temperature so that it
does not fall below 0°C.
- Cleaning - extraordinary maintenance and
reinstatement operations must be carried
out by an authorised service centre.