Rollixo io
> Operation with cells
An obstacle placed between the cells will prevent the door from closing.
If an obstacle is detected while the door is closing, it stops, then re-opens fully.
The receiver warning light
> Operation with the alarm
The alarm is triggered for 2 minutes if the door is raised manually. No movement
of the door is possible when the alarm is sounding.
When the alarm sounds, press a button on a remote control memorised in the
receiver to stop it. The alarm can only be stopped with a memorised remote
control.
> Operation in automatic closing mode
Automatic closure of the door occurs after a time delay programmed during
installation.
A new command during this time delay cancels automatic closing and the door
remains open.
The following command results in the closure of the door.

4.3 Adding remote controls

This operation must be carried out close to the receiver.
This operation is used to copy the function of a button on a memorised Keygo
io remote control to a button on a new Keygo io remote control.
[1]. Press the outer left and right buttons on the previously memorised remote
[2]. Press the button to be copied on the remote control already memorised
until the indicator light on top of the
permanently.
[3].
together.
[4].
control.
The indicator light above the
remote control is stored in the receiver.
[1]
[2]
[3]
[4]
Copyright © 2014 Somfy SAS. All rights reserved.
button on the receiver comes on
Prog
Prog
Remote control
memorised
Prog
Remote control to be
memorised
Prog

5 - OPERATING DIAGNOSTICS

The indicator lights on the front of the Rollixo receiver notify the user of the
installation's status.
Safety edge
Motor
Fall protection
1
STOP
Indicator light status
Meaning
Off
Functional installation
Deactivation/activation in progress
Permanently lit
Installation fault/failure
Diagnostics
Motor
Consequences
Actions
Diagnostics
Consequences
Actions
Radio safety
edge
Diagnostics
Consequences
Actions
Diagnostics
Consequences
Actions
Safety edge
transmitter batteries
Photoelectric
cells
2
3
4
Prog
Indicator light status
Activated motor thermal protection
No movement possible
Wait around 10 minutes.
Radio interference on the safety edge
transmitter
Opening and stopping ok
Closing by pressing and holding down
the button within sight of the door
If a powerful radio system is present on
etc.) and is transmitting on the same
frequency, the receiver will wait for the
transmission to end to before controlling
the door again.
Safety edge transmitter low battery
indication.
Opening ok
Closing by pressing and holding down
the button within sight of the door
If the fault persists, replace the safety
edge transmitter batteries.
Obstacle detection
Remove the obstacle by automatic partial
opening
Check that no obstacle is causing the
safety edge to detect.
Prog