sUMMER UsE

The system must be completely filled with water. The absence of water in the system would lead to serious damage of the entire structure.
ATTENTION: For no reason must the fire be ignited before the system has been completely filled with water; doing this would lead
to serious damage of the entire structure.
In order to prevent water boiling, the circulation pump must be always in function in order to drain on the radiators, or on the puffer, or on any
other thermal absorption structure the heat given from the boiler to the water.
If the pump does not circulate or for any reason the water temperature exceeds 95°C, acts the DsA valve discharging heat
in the throughway water. It is recommended to supervise the water temperature in the thermoproduct during summer use
to avoid recurrent interventions of the DsA valve which may jeopardize its good operation.

MAINTENANCE AND CARE

Check the external air intake, by cleaning it, at least once a year. The stack must be regularly swept by the chimney sweeper.
Let your chimney sweeper in charge of your area check the regular installation of the device, the connection to the stack and the aeration.
IMPORTANT: The maintenance must be carried out only and exclusively with cold device .you should only use spare parts
approved and supplied by La NORDICA s.p.A. . Please contact your specialized retailer if you require spare parts.
YOU MUsT NOT MAkE ANY CHANgEs TO THE DEVICE!!!

gLAss CLEANINg

Thanks to a specific inlet of secondary air, the accumulation of dirty sediments on the glass-door is reduced with efficacy. Nevertheless this can
never be avoided by using solid fuels ( particularly wet wood ) and it has not to be understood as a defect of the appliance.
IMPORTANT: The cleaning of the sight glass must be carried out only and exclusively with cold device to avoid the explosion
of the same. For the cleaning, it is possible to use specific products or a wet newspaper paper ball passed in the ash to rub it.
Do not use cloths, abrasive or chemically aggressive products by cleaning the hearth glass.
The correct lighting phase, the use of proper quantities and types of fuels, the correct position of the secondary air regulator, enough draught
of the chimney-flue and the presence of combustion air are the essential elements for the optimal functioning of the appliance and for the
cleaning of the glass.
BREAk OF gLAssEs: given that the glass-ceramic glasses resist up to a heat shock of 750°C, they are not subject to thermal
shocks. Their break can be caused only by mechanic shocks (bumps or violent closure of the door, etc.). Therefore, their
replacement is not included in the warranty.

CLEANINg OUT THE AsHEs

All the devices are equipped with a hearth grating and an ash drawer for the collection of the ashes.
It is suggested to empty periodically the ash drawer and to avoid it fills completely in order not to overheat the grating. Moreover, it is
suggested to leave always 3-4 cm of ash in the hearth.
CAUTION: The ashes removed from the hearth have to be stored in a container made of fire-resistant material equipped
with an air-tight cover. The container has to be placed on a fire-resistant floor, far from flammable materials up to the
switching off and complete cooling.

CLEANINg THE FLUE

The correct lighting phase, the use of proper quantities and types of fuels, the correct position of the secondary air regulator, enough draught
of the chimney-flue and the presence of combustion air are the essential elements for the optimal functioning of the appliance.
The device should be completely cleaned at least once a year or every time it is a needed (in case of bad working and low yield). An excessive
deposit of soot can cause problems in the discharge of smokes and fire in the flue.
The cleaning must be carried out exclusively with cold equipment. This operation should be carried out by a chimney sweeper
who can simultaneously perform an audit of the flue (checking of possible deposits).

sUMMER sTOP

After cleaning the hearth, chimney and hood, totally eliminating the ash and other eventual residues, close all the doors of the hearth and
the relevant registers; in case you disconnect the appliance from the chimney you must close its openings in order to let work others possible
appliances connected to the same flue.
We suggest performing the cleaning operation of the flue at least once per year; verifying in the meantime the actual status of the rope seals,
which cannot ensure the good operation of the equipment if they are not in good condition and are not making a good seal! In this case the
seals must be replaced.