Herunterladen Inhalt Inhalt Diese Seite drucken

Access To Menus; Limit Switch Adjustment - BFT ARGO G Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
Press the OK key
Control unit software version
N. total manoeuvres (in tens)
N. manoeuvres since latest maintenance (in tens)
N. radio control devices memorised
end
logic
end
radio
end
lingua
end
default
end
autoset
end
l. s w adj
end
12 -
ARgO-ARgO g
param. 1
param. 2
param. . . .
logic. 1
logic. 2
logic. . . .
hidden button
add. start
Add. 2ch
hidden button
read
erase 64
PRG.
COD RX
1 A 9 C
v
ITA
OK
- +
FRA
OK
- +
DEU
OK
- +
ENG
OK
- +
esp
OK
PRG

LIMIT SWITCH ADJUSTMENT

ACCESS TO MENUS

See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
01 t1
See RADIO MENU
+/-
2 2 F D
0 1
OK
OK
Logic
PED
STRe
STOP
PHOT
BAR
CLOS
OPEN
Suo
Suc
A P
Set
ER01
ER02
(Fig. F)
ER10
ER11
ER21
ER40
ER50
35.40
Scroll up
Cancel/return to main menu
Scroll down
Confirm/Switch on display
o 01
o 01
OK
Description
partial opening input activated
START input activated
STOP input activated
PHOT input activated
SAFETY EDGE input activated
CLOSE input activated
OPEN input activated
opening limit switch activated
closing limit switch activated
reverse due to obstacle
autoset function is running
WARNING! Obstacle detection function is not active
photocell test error
safety edge test error
mosfet test error
shunt test error
encoder test error
thermal cutout error
optional module communication error
Set torque threshold %
Maximum motor torque %

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Argo

Inhaltsverzeichnis