Operating Instructions
GB
Dear Customer,
Congratulations on purchas-
Please familiarise yourself with
ing your new STEINEL pres-
these instructions before at-
ence detector and thank you
tempting to install the pres-
for the confidence you have
ence detector because pro-
shown in us. You have chosen
longed, reliable and trouble-
a high-quality product that has
free operation will only be en-
been manufactured, tested
sured if it is fitted and used
and packed with the greatest
properly.
care.
Safety Precautions
personal injury or damage
í The presence detector
to property.
must only be installed by a
í This product must never be
qualified electrician in ac-
connected to a 230 V AC
cordance with national
power supply as it is in-
wiring regulations as de-
tended for connection to
fined in VDE 08 29
an extra-low voltage power
(DIN EN 5000  90).
í Installed improperly, low-
supply.
voltage products can
cause extremely serious
System Components
Sensor module
Surface-mounting adapter
Metal frame
Catch mechanism
Sensor base
Reach setting
k
4.
Kaiser stud-wall junction
Programming button
1
box, optional
Installation and wiring
k
4.
2
clamping-type ceiling
adapter UP Box
Installation / Wiring
The sensor is only suitable
for recessed ceiling installa-
tion indoors. A clamping-type
ceiling adapter or surface-
mounting adapter is not
included.
PC PRO KNX_Zentraleuropa.indd 14-15
PC PRO KNX_Zentraleuropa.indd 14-15
We hope your new STEINEL
sensor will bring you lasting
pleasure.
Shrouds for minimising
the detection zone
(HF 360 KNX).
- 14 -
Accessories
Kaiser junction box for stud
Guard cage
walls
EAN no.: 4007841003036
EAN No.: 4007841 000370
RC6 KNX service remote
Clamping-type ceiling adapter
control
EAN No. 4007841 002855
EAN no.: 4007841 593018
Surface-mounting adapter
User remote control
AP Box KNX
RC7 KNX
EAN no.: 4007841 003029
EAN no.: 4007841 592912
How it Works / Basic Function
The infrared and HF presence
Using modern, high-frequency
detectors from the Control
technology, the HF 360 guar-
PRO range control lighting as
antees detection of movement
well as HVAC, e.g. in offices,
absolutely anywhere irrespec-
schools, public buildings or at
tive of radiated temperature.
home, in relation to ambient
light level and the presence of
Sensing movement in two di-
persons.
rections, the DUAL HF-sensor
is ideal for corridors in hotels,
The IR Quattro with highly ad-
schools and office buildings.
vanced lens provides a square
detection zone, as the typical
Presence Control has a low in-
shape of a room, in which the
trinsic power consumption.
smallest of movements are
sensed.

Operation

Note: To calibrate the pres-
2. Load the Physical Address
ence detector, please go to
and Calibration Program
www.knx.steinel.de
into the presence detector.
When you are prompted to
1. Issue Physical address
press the programming
and generate calibration
button (8).
programme in the ETS.
í Presence detection
í Controlling lighting with
brightness control
í HVAC control
The function to be used (acti-
vated) is defined by the "Gen-
eral Settings" parameter win-
dow using the ETS3.f version
of the Engineering Tool Soft-
ware (ETS) and higher.
3. The blue LED goes out
once programming has
been successfully com-
pleted.
- 15 -