Herunterladen Diese Seite drucken

Lenz Digital plus LS100 Information Seite 39

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Failure
When a LS100 is
addressed, the display
of the LH100 shows the
following:
When programming at
the programming
output of the command
station, the manual
control shows the error
message "ERR02".
When programming at
the programming
output of the command
station, the manual
control shows the error
message "ERR02".
Possible cause
The point address
entered is not occupied
by a switch decoder but
feedback module
LR100/101.
The command station
cannot verify the
programming
procedure since no
load is connected at the
output of the
LS100/110.
The connection
between the
programming output of
the command station
(terminals P and Q)
and the LS100 is
incorrect.
Correction of failure
Enter the correct point
address. Check
whether you have
accidentally
programmed
overlapping addresses
(see "Der gemeinsam
belegte Adressbereich
von " on Page 12.
Connect a point drive
or bulb to one of the
outputs of the LS100.
See "Einstellung von
Adresse
(Programmierung) und
Eigenschaften am
Programmierausgang"
on Page 13.
Check and correct the
connections.
39
E

Werbung

loading