24
Figure 1
Connection to the digital system and/or separate power supply
There are two ways of connecting the LS100: connection with or without a
separate power supply. We recommend a connection with a separate power
supply since the power required for switching is not taken from the track and
therefore does not put a strain on the "digital current".
Connection with a separate power supply:
Connect terminals J and K to the track output of the digital system. In the
®
Digital plus by Lenz
system, the track output is also marked J and K.
Connect the () terminals to the terminals of the transformer. Observe the
maximum permissible voltage (see Technical data). We recommend the use of
®
the Digital plus by Lenz
transformer TR100 (art. no. 26000).