The WABCO Leakage Detector and accessories do not require maintenance.
Use a lightly dampened cloth with a detergent-free cleaning agent for cleaning.
The device must not be disposed of together with household refuse.
Observe and follow national regulations on electronic waste.
Fault
Device will not switch on.
Acoustic signal can not be
detected, green indicator
lit.
Red Charging LED
flashes.
No function even though
the battery was charged,
green indicator does not
light up.
Possible cause
Discharge battery.
Volume controller set
too low.
Probe not connected
properly.
Headphones not con-
nected properly.
Device has switched
itself off automatically.
Probe or probe cable
defective.
Internal battery defective.
Charging circuit defective.
Device or charger defec-
tive.
Remedy
Recharge battery
Increase volume.
Completely plug in
connector.
Completely plug in
connector.
Switch device on
again.
Device needs to be
repaired. Speak to
your WABCO partner.
Device needs to be re-
paired. Speak to your
WABCO partner.
Device needs to be re-
paired. Speak to your
WABCO partner.