Product Description
B
Aquarius Eco Expert 22000/28000
1
Pump casing
The position of the outlet can be changed by fitting the pump casing rotated through 90°.
2
Outlet (pressure socket)
3
Inlet (suction socket)
4
Filter housing
5
Stand
Ensures secure and stable positioning of the pump.
Can be firmly bolted to the ground.
6
Connection OASE Easy Garden Control (EGC)
The pump can be controlled via EGC with Eco Control or InScenio FM-Master WLAN (optional).
This manual does not contain a description of the connection and operation of EGC. For information please contact your specialist dealer
or OASE.
Important: Moisture at the connections can damage the pump.
Only remove the protection caps for connecting the EGC lines.
Ensure that the rubber seals are clean and fit exactly.
Replace damaged rubber seals.
7
Switch for switching on/switching off the Dynamic Function
Properties
Excellent delivery rates meeting the requirements of demanding filter systems and large water courses and waterfalls.
Can deal with coarse debris with a particle size of up to 4 mm.
Ergonomic handle for safe transport.
Suitable for immersed or dry installation.
Unique, patented frost protection: The pump is guaranteed to operate without damage at temperatures as low as
-20 °C.
Suitable for swimming ponds and natural swimming pools (installed in an external pump chamber).
Dynamic Function
Different values for the pump flow rates are pre-programmed in the pump control system to allow a dynamic fountain
pattern with changing heights and diameters. When the Dynamic Function is activated, the pump is continuously con-
trolled with these values.
Intended use
Aquarius Eco Expert 22000/28000, referred to as "unit", may only be used as specified in the following:
Pumping of normal water for creating fountains.
Operate in accordance with instructions.
Operation under observance of the permissible water quality. ( Water quality)
The following restrictions apply to the unit:
Do not use in swimming ponds.
Never use the unit to convey fluids other than water.
Never run the unit without water.
Do not use for commercial or industrial purposes.
Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
Do not connect to the domestic water supply.
- EN -
15