Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch ARD-AYH12 Installationshandbuch Seite 8

Vorschau ausblenden Andere Handbücher für ARD-AYH12:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

8
en | Installation Manual
TECHNICAL SPECIFICATIONS
Electrical Characteristics
Power Supply Type
Operating Voltage Range 5 - 16 VDC
Maximum Input Current
Tamper Output
Max Cable Distance to
Controller
Output modulation
Card read distance*
RF Modulation
Regulatory Approvals
Environmental Characteristics
Operating Temp. Range
Operating Humidity
Dimensions
Height x Widht X Depth
* Measured using Bosch Proximity Card (P/N ACD-ATR11ISO) or
equivalent. Range also depends on electrical environment and/
or proximity to metal.
Suitable for Outdoor Use
| V 1.2 | 2009.09
Linear type recommended
Standby: 35 mA
Read: 50 mA
Open collector, active low, max
sink current 16 mA
500 ft. (150 meters)
26-bit Wiegand
3.93 inch (10 cm)
ASK
USA: UL 294 & FCC Part 15B
Europe: CE Listed
-25°F to 145°F (-31°C to 63°C )
0 to 95% (non condensing)
4.72 x 1.65 x 0.55 inch
(119.95 x 41.95 x 14 mm)
Bosch Sicherheitssyteme GmbH
ARD-AYH12

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis