With the exception of models COR-F-1000 FT
and COR-F-1500 FT that can only be used as
cold air curtains the other devices in this series
can be used as either hot or cold air curtains.
Please check that the unit is in perfect state
when you unpack it, as any manufacturing
defect is covered by the S&P guarantee.
IMPORTANT INSTRUCTIONS
SAFETY WARNINGS
The unit should not be located directly above
or below an electrical power point.
Do not cover it with objects or garments that
could impede the free circulation of air.
Covering the unit may cause it to overheat.
While in operation, the power cable should not
be in front of the air outlet.
If installed in a bathroom, it should be fitted in
such a manner that the switches or other
controls cannot be touched by a person while
in the bath or shower. All inflammable objects
should be kept at least 50 cm away from the
hot air circuit (curtains, etc).
Keep the air inlet and outlet grilles clean.
Before cleaning the unit or manipulating
anything inside it, make sure it is disconnected
from the mains supply.
Do not manipulate the appliance with wet
hands.
This appliance should be installed by an
electrician.
IMPORTANT:
THESE UNITS MUST
ALWAYS BE EARTHED.
The disconnection device to be incorporated
to the electrical wiring system for cutting the
mains power supply of both poles should have
at least 3 mm clearance between the contacts
of the poles.
For operation as an air curtain, the distance
from the floor should be no greater than 4
metres.
The minimum distance between the curtain
and the floor should be 2.5 metres.

INSTALLATION

The unit must be secured to an appropriate
surface for this application.
Observe the minimum distances as indicated
in Fig.1.
This is the process for installation:
First, choose the fitting option according to the
type of ceiling and space available: LOWER
FASTENING OPTION (Fig. 4). UPPER
FASTENING OPTION (Fig. 5). Then fit the
threaded rods (or Rawplugs) with their nuts,
following the dimensions indicated in the
illustration in Figs. 2 and 3.
Next, fit the curtain making sure it is level with
the plates of the false ceiling, so that when the
grille is installed with the bolts (A) Fig. it will fit
to the ceiling.
ELECTRICAL WIRING (Figs. 7 and 8)
These units are for fixed installation. When
connecting to the mains supply, apply the
guidelines indicated in the Low Voltage
Regulations as well as any applicable national
regulations.
The installation should have a circuit breaker
or some other type of device for complete
disconnection of the power supply to the unit.
Before connecting to the mains supply, check
that the voltage is the same as that indicated
on the specifications plate of the unit.
Use cable with a section and number of wires
as indicated in the diagrams corresponding to
each model.
Secure the cables with glands.
STARTUP AND OPERATION
CONNECTING THE REMOTE CONTROL.
(This control is included in packaging box of all
curtains).
CURTAIN MODEL
COR-F-1000 FT
COR-F-1500 FT
COR-6-1000 FT
COR-9-1500 FT
8
REMOTE CONTROL MODEL
CR-F
CR-F
CR-6/9 N
CR-6/9 N