The detector can be associated with a DELTA DORE wireless X3D
alarm and control system.
Functional check and maintenance:
You must check that your detector is functional once
a month or after each battery change.
Pressing the "test" button on the case for a few
seconds will light up the LED and the detector will
emit 2 beeps.
Do not try to trigger the alarm any other way (using a lighter, etc.) because
you could damage the detector or even start a fi re.
Your detector has been designed to require the minimum maintenance pos-
sible. However, some simple actions need to be performed once a year.
After having removed the detector:
• Clean the cracks in the detector (located on the side) with a vacuum
cleaner, using a soft brush or a vacuum cleaner accessory.
• Use a slightly damp cloth to clean the outside of the case.
It is recommended that the detector be replaced after 10 years.
Additional installation recommendations, as well as the "Mandatory
Performance Declaration" for this equipment are available in the
product fi le for DFR TYXAL+ on our website www.deltadore.com
Material manufactured by SHD BP10809 under reference DOF79R.
2. Location

Locations to avoid

Do not install the detector:
• Within a metre from vents for heating, cooling or circulating air.
The smoke could be blown away from the detector or be diluted.
• In a place where the temperature could drop beneath 0°C or rise above
+50°C;
risk of detector not working correctly.
• In a place where there is a risk of condensation. Bathrooms and laundry
rooms are not recommended.
• Places where smoke could gather (kitchen or poorly ventilated garage)
and cause false alarms.
• In a place that is excessively dusty.
- 8 -
2. Location
Recommended locations:
In the home:
• For enhanced protection:
- Place a detector in each room, avert using listed places to avoid.
• For basic protection:
- Place a detector on each fl oor.
- Place a detector close to sleeping areas
(for example, in the corridor leading to rooms; in the case
of a long corridor > 10m, place 1 detector at each end).
- Place a detector in each bedroom occupied by a smoker.
Basic protection
Enhanced protection
Kitchen
Bedroom
Bedroom
Dining
room
Lounge
Smoker
bedroom
Flat
In the room:
• The detector should preferentially be at-
tached to the ceiling in the middle of the room.
Otherwise, attach it more than 20cm from any
obstacle (partition wall, beam, etc.) and over
15-25
60cm from any room corner.
cm
• If this is impossible, attach the detector to
the wall at a distance of between 15 and 25cm
from the ceiling.
20 cm
• In the case of an angled ceiling, attach the
detector at a location between 20 and 90 cm
vertically below the highest point.
90 cm
Corridor
Bedroom
Bedroom
Kitchen
Lounge
Basement
House