c) Distance measurement (mode not displayed)
Press the button M to select the "distance measurement" mode (mode not displayed).
Point the distance meter to the spot to be measured and then press the button
measured distance will be shown in the panel of the eyepiece.
The device will automatically turn off after a few seconds in order to save
energy. Reactivate the device by pressing the button
d) Continuous distance measurement (Scan)
In "distance measurement" mode press and hold the button
mode. "Scan" appears in the panel of the eyepiece after about 2 – 3 seconds. Continue
to press and hold the button
. When in scan mode, the laser is permanently activated
and the device will show the distances to the scanned objects one after another. The
scan mode will automatically stop after 20 successive distance measurements. The
distance measured last will be displayed in the eyepiece panel until the device turns
off automatically or until you select another mode.
e) Distance measurement with fixed spot (Scan with flag symbol)
Using the distance measurement with fixed spot will allow you to exclude background
objects from the measurement when e.g. watching wildlife in the woods. Press the
button M to select the "Scan" mode (with flag symbol). Press and hold the button
to start measuring. Target an object until the device displays the distance. Continue
targeting the object while keeping the button
object moves slowly, the device will show the distance between the viewer and the
object. Keep in mind that only a distance of more than approx. 5 m will be displayed.
f) Fog mode (Fog)
The fog mode can compensate for any adverse effects caused by fog during distance
measurements in most of the cases. But keep in mind that the fog mode will not work
when measuring the distance against thick fog, since the fog will split the radiation.
The fog mode is intended as an aid for light fog or weather with poor visibility. Use the
button M to select the fog mode. "Fog" will appear in the panel of the eyepiece. Then
press the button
to start measuring.
g) Speed measurement (Speed)
The speed mode measures the time an object needs to move from one point to
another. Use the button M to select the speed measurement mode. "Speed" appears
in the panel of the eyepiece. Press and hold the button M for approx. 3 seconds in
order to select measuring units KM/H (kilometers per hour) or M/H (miles per hour).
The measuring unit will change accordingly. Press the button
in the eyepiece panel starts flashing. Target a moving object and keep the distance
meter pointed at the targeted object for a few seconds. After approx. 3 – 4 seconds the
measured speed will be displayed in the panel of the eyepiece.
. The
again.
to select the scan
pressed. If you move or the targeted
. The targeting frame
Carry strap
If needed, attach the carry strap to the eyelet (4) on the right side underneath the
eyepiece.

Maintenance and cleaning

• Do not use any aggressive cleaning agents or chemical solutions as they may cause
damage to the housing or lenses.
• Do not immerse the product in water.
• Clean the lenses with the cleaning cloth provided. Do not apply too much pressure
to the lens to prevent scratching.
• Clean the housing with a soft, lint-free cloth or a dust brush. If necessary, you can
moisten the cloth with a little lukewarm water.
Disposal
a) Product
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product in accordance with
applicable regulatory guidelines.
Remove any inserted (rechargeable) batteries and dispose of them
separately from the product.
b) (Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/
rechargeable batteries. Disposing of them in the household waste is prohibited.
Contaminated (rechargeable) batteries are labeled with this symbol to
indicate that disposal in the domestic waste is forbidden. The designations
for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead
(name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used batteries/rechargeable batteries can be returned to collection
points in your municipality, our stores or wherever batteries/rechargeable
batteries are sold.
You thus fulfill your statutory obligations and contribute to the protection of the
environment.

Technical data

Operating voltage................................1 x 3 V battery, type CR2
Magnification.......................................6 x 21
Lens Ø ...................................................21 mm
Prism glass ...........................................K9
Range ....................................................5 to 1000 m
Field of view angle ..............................7.2°
Field of view at 1000 m .......................126 m
Exit pupil ...............................................3.5 mm
Distance to eyes..................................16 mm
Twilight factor ......................................11.2
Speed measuring range.....................0-300 km/h
Measuring accuracy ..........................+/-1 m / yd
Protection type ....................................IPX3
Tempering .............................................full multi-coating
Luminosity ............................................12.3
Laser class ...........................................I
Wavelength ..........................................905 nm
Operating conditions ..........................-10 to +50 ºC, 0 – 90 % RH (non-condensing)
Storage conditions..............................10 to +50 ºC, 0 – 80 % RH (non-condensing)
Dimensions (W x H x D)......................35 x 73 x 106 mm
Weight ...................................................approx. 152 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represents the
technical status at the time of printing.
© Copyright 2017 by Conrad Electronic SE.
V2_0717_02-HK

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis