4 Connection
Connect the enclosed cable according to the follo-
wing list with the alarm center and its plug in the CN3
socket.
The connection 6 is switched via a transistor to
ground for 0.5 seconds if for 9 times a wrong code
number has been entered. With corresponding con-
nection to the alarm center by this an alarm can addi-
tionally be released.
The red and green LEDs of the keypad controller
serve as a state indication of the alarm center and
can be connected in parallel with the indications of
the alarm center, e. g. green LED = alarm center
activated, red LED = alarm. If in the alarm center
there are already series resistors for the red and
green LEDs of the keypad controller, the 1 kΩ series
12
1 red
2 black
3 grey
4 grey
5 orange
6 brown
7 black
8 blue
9 black
10 green
11 white
12 violet
13 yellow
(+) 8-13.8 V
(-) ground
anti-tamper switch (NC)
anti-tamper switch (NC)
not connected
signal if wrong number entered
9 times
red LED negative
red LED positive
green LED negative
green LED positive
NC relay contact
common relay contact
NO relay contact