d) System Setup

• Keep the button "SET" (6) pushed for 5 seconds until the upper display line shows "F1".
• Use the buttons " " (5) and " " (8) to select the functions "F1" to "F11" (see description in the table and on the
following pages).
If you do not push any button for 10 seconds, setting mode is left automatically. The settings made are
saved.
• When you have selected the chosen function (e.g. "F3"), briefly push the button "SET" (6) to confirm.
• Change the setting with the buttons " " (5) and " " (8). Keep the respective button pressed for quick adjustment.
• Briefly push the button "SET" (6), to save the setting and return to selection of the functions "F1" to "F11". Then you
can select and set another function.
• To leave setting mode, briefly push the button "AUX/
The settings made are saved.
Function
Description
F1
Sets the temperature for hysteresis
F2
Sets the delay time for switching between cooling and heat-
ing mode
F3
Calibrates the temperature
F4
Sets the delay time for restart of the cooling unit
F5
Sets the password for access to the system setup
F6
Sets the counter for starting defrosting
F7
Sets the time for defrosting
F8
Selects the operating mode
F9
Sets the difference for the temperature alarm
F10
Sets the delay time for the temperature alarm
F11
Sets the delay time for the temperature alarm (after switching
on the temperature controller)
30
" (4). Alternatively, do not push any button for 10 seconds.
Setting
range
0....10.0
0....60
-5.0....5.0
0....10
0....999
0....999
0....60
0....1
1....20
0....90
0....10
Default
Unit
Setting
2.0
°C
10
minutes
0
°C
3
minutes
0
-
60
minutes
10
minutes
0
-
10
°C
20
minutes
2.0
hours