12. DISPOSAL

Dispose of the product at the end of its serviceable life in accordance with the current statutory requirements; e. g. return it to any suit-
able collecting point.

13. TECHNICAL METER DATA

Meter type: ..................................................Rotary current meter (with backflow lock)
Meter type: ..................................................Only positive energy counted, backflow lock (like motor counter)
Accuracy class ..........................................Class A (2%) pursuant to EN50470-1
Reference current I
: ................................5 A
ref
Threshold current I
: ..............................60 A
max
Start-up current I
: ....................................10 mA
st
Minimum current I
: ................................100 mA
min
Transition current I
: ..................................500 mA
tr
Reference voltage U
: ................................4-conductor meter: 3 x 230/400 V, 2-conductor meter: 230 V in L2
n
Reference frequency f
: ............................50 Hz
n
Meter constant: ..........................................LED output (red) at 10,000 Imp/kWh
LC display: ..................................................7 pre-decimal-, 1 post-decimal digit
Clamp Ø: ....................................................8 clamps, each at Ø 6.5 mm (60 A DIN), screws 2 x M5 per clamp
Outputs: ......................................................Optical impulse output according to EN50470-1
Weight: ......................................................Approx. 0.6 kg
Protection class: ........................................II
Protection type (casing): ............................IP54
Power consumption: ..................................<=0.005 W at 5 A / <=1.1 W at 60 A in the power path
Temperature range: ....................................-25 °C to +55 °C
Air humidity: ................................................<100 %
Mechanical /( EMC requirement class: ......M1 / E2
Meter use: ..................................................Indoors
Dimensions: ................................................191 x 177 x 50 mm
Assembly
Recommended conductor cross-section for connecting the meter: ....16 mm
Max. tightening torque of the clamp screws: ......................................<=3 Nm
Clamp lid available in 4 lengths. ..........................................................30, 60, 80, 100 mm
Slanted installation of the meter does not influence the measuring unit.
<=0.6 W / 2.5 VA in the voltage path