Example B
Description: Power is supplied only once to ORION and also used for the input equipment. Each
Port is protected with 500 mA max. To Port 1, a PNP output sensor is connected over 0 V – 12 V.
To Port 2, an NPN output sensor with an open collector is connected plus a 1k Ω – 10k Ω resistor.
Example C
Description: Power is supplied to ORION and supplied separately to the input equipment. The
sensor is connected to Port 1 via GROUND and DATA at Pin 1, but not V+!
Example D
Description: 5 V – 24 V power is supplied externally and to all input equipment. For example, a
sensor is connected to Port 1 via GROUND, DATA at Pin1, and V+ to supply power to ORION once,
while a second sensor is connected to Port 2 via GROUND and DATA at Pin 5, but not V+!