Follow the safety instructions and the other information in this operation manual.
• Plug the countdown timer into a standard earthed mains socket (wall socket). The power LED
on the countdown timer lights up.
• Plug the consumer into the socket on the front of the countdown timer; make sure the plug is
pushed into the socket fully.
• If the consumer connected to the countdown timer has a power switch, switch it on (the
switch setting marked e.g., "ON" or "I").
• Repeatedly press the "ON/SET" button on the front of the countdown timer as many times as
needed until the LEDs display the desired switched-on period (15, 30, 45 or 60 minutes).
The socket on the front of the countdown timer is thereby switched on.
• After the set time has expired, the socket on the front of the countdown timer is switched off
and thereby the connected consumer.
In every case, during the fi nal minute of each 15-minute period, the LED blinks
slowly, in the last 20 seconds quickly.
Example:
You set the timer for 30 minutes; the LED "30" lights up; the countdown starts auto-
matically.
After 14 minutes (with 16 minutes remaining), the LED "30" starts to blink. After one
minute (with 15 minutes remaining), the "30" LED goes out and the "15" LED lights
up.
After another 14 minutes (with 1 minute remaining), the LED "15" starts to blink.
After the fi nal minute has expired, the LED "15" goes out and the consumer con-
nected to the countdown timer socket is switched off.
The timer count has fi nished.
• If you press the "ON/SET" button during the timer countdown (multiple times if needed), the
timer is reset and starts again with the switched-on period (15, 30, 45 or 60 minutes) just set.
• You can end the timer count early, and turn off the connected consumer, by briefl y pressing
the "OFF" button.

Maintenance and Cleaning

• The product does not require maintenance. The product contains no parts that require servic-
ing. Therefore, do not open/dismantle it. Maintenance or repairs may only be performed by
qualifi ed personnel or a specialised repair shop.
• Before cleaning, disconnect the countdown timer from the power supply. To do this, unplug it
completely from the mains socket (the wall socket).
• Use a clean, dry, soft cloth for cleaning.
• Dust can be removed easily using a clean, soft and long-haired brush and a vacuum cleaner.
Do not use abrasive cleaning agents, cleaning alcohol or other chemical solutions,
since these could damage the housing or even impair operation.
Disposal
Dispose of the unserviceable product according to the relevant statutory regulations!

Technical Data

Operating voltage .........................230 V/AC, 50 Hz
Power consumption ......................<1.5 W
Switching capacity ........................max. 1800 W
Protection class ............................I
Model: ...........................................Relay; 1-pole switch
Timer settings ...............................15, 30, 45 or 60 minutes
Ambient temperature ....................0 °C to +40 °C
Ambient air humidity .....................0% to 90% relative air humidity, not condensing
Dimensions ...................................64 x 120 x 47 mm (W x H x D)
Weight ..........................................approx. 150 g
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2011 by Conrad Electronic SE.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis