Operating instructions
Transponder code lock
Item no. 1582599 / for surface mounting
Item no. 1582600 / for flush mounting
Intended use
This product is designed to secure access to doors. Separating the code lock (mounted next to
the door) and the control unit (mounted indoors) provides additional manipulation and access
protection.
Access can be granted with a user code or a battery-free transponder card.
The code lock can be mounted indoors and outdoors (IP66). The control unit must be installed
and used in dry indoor areas.
The code lock and the control unit work with an operating voltage of 12–24 V / DC.
This product is intended for indoor use only. Do not use it outdoors. Contact with moisture (e.g.
in bathrooms) must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. Using the
product for purposes other than those described above may damage the product. In addition,
improper use can cause hazards such as a short circuit or fire. Read the instructions carefully
and store them in a safe place. Only make this product available to third parties together with
its operating instructions.
This product complies with statutory national and European regulations. All company and
product names are trademarks of their respective owners. All rights reserved.
Up-to-date operating instructions
To download the latest operating instructions, visit www.conrad.com/downloads
or scan the QR code on this page. Follow the instructions on the website.

Package contents

a) Item no. 1582599
• Code lock with surface-mounted housing
• Control unit
• Mounting materials for code lock (3x screws, 3x dowels, 1x diode)
• Mounting materials for control unit (2x screws, 2x dowels, 1x diode)
• 1x connection cable harness with connecting plug
• TX hex key for the code lock
• 2x transponder cards
• Detailed instruction manual (German printed and online, English online only)
• Operating instructions
b) Item no. 1582600
• Combination lock with flush-mounted housing
• Control unit
• Mounting materials for code lock (4x screws, 4x dowels, 1x diode)
• Mounting materials for control unit (2x screws, 2x dowels, 1x diode)
• 1x connection cable harness with connector plug
• TX hex key for the code lock
• 2x transponder cards
• Detailed instruction manual (German printed and online, English online only)
• Operating instructions

Explanation of symbols

The symbol with the lightning in a triangle indicates that there is a risk to your health,
e.g. due to an electric shock.
The symbol with an exclamation mark in a triangle is used to highlight important
information in these operating instructions. Always read this information carefully.
The arrow symbol indicates special information and advice on how to use the
product.
This product must only be used in dry, enclosed indoor areas. It must not become
damp or wet, as this may cause a fatal electric shock!

Safety instructions

Read the operating instructions and safety information carefully. If you do
not follow the safety instructions and information on proper handling in this
manual, we will assume no liability for any resulting personal injury or damage
to property. Such cases will invalidate the warranty/guarantee.
a) General information
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly, as it may become
dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, stop using it and prevent
unauthorized use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stress.
• Always handle the product carefully. Jolts, impacts or a fall even from a low height
may damage the product.
• Always observe the safety and operating instructions of any other devices which
are connected to the product.
• Consult a technician if you are not sure how to use or connect the product.
• Maintenance, modifications and repairs must be done by a technician or a
specialist repair centre.
• If you have questions which remain unanswered by these operating instructions,
contact our technical support service or other technical personnel.
b) Persons and product
• The code lock has an IP66 protection rating, meaning that it can be installed and
used both indoors and outdoors.
• The control unit must be installed and used in dry indoor areas.
• Make sure that the connection cable is not pinched or damaged by sharp edges.
• Always comply with the accident prevention regulations for electrical equipment
when using the product in commercial facilities.
Mounting
a) Preparations for mounting and selecting the mounting location
• The product must be mounted and connected by a qualified technician. There are a wide
range of connection and programming options, allowing you to configure the code lock to
your individual needs.
• We therefore recommend that you program and test the system before mounting it in a
fixed position (if possible). This helps to plan the wiring correctly and avoids unnecessary
troubleshooting.
• The code lock can be mounted indoors and outdoors (IP66). The control unit must be
installed and used in dry indoor areas.
• The code lock must be installed directly next to the door that you wish to control.
• The control unit should be placed in a protected and tamper-proof location so that it cannot
be accessed by visitors and guests.
• The cable between the code lock and the control unit must not be too long (we recommend
a maximum length of 10 m). If possible, use the connection cable without an extension lead.
• Always lay the cable where it is protected and concealed, e.g. under plaster or in a suitable
installation pipe.
• The code lock and control unit must be supplied with a stabilised voltage of 12–24 V DC.
• The code lock and control unit require a maximum current of approximately 145 mA and 100
mA respectively. Use a battery-powered backup system to ensure that the code lock and
control unit will continue to function during a power cut.