d) Stopwatch function
• Press the ST/STP (3) key to start the stopwatch.
• Press the ST/STP (3) key to stop the stopwatch.
• With the ST/STP (3) key, the stopwatch can be restarted.
• Press the RESET (1) key after you have stopped the stopwatch to reset the stopwatch to
"0:00:00".
• While the stopwatch is running you can display a split time by pressing the RESET (1) key. The
display indicates the split time but the stopwatch continues to run in the background.
• Press the RESET (1) key again to return to the stopwatch display.
e) Countdown timer
Setting the time target
• Press the RESET (1) key.
• Increase the target value for the hours using the ST/STP (3) key or decrease it with the LIGHT
(4) key.
• Press the MODE (2) key to switch to the next setting step (minutes).
• Increase the target value for the minutes using the ST/STP (3) key or decrease it with the LIGHT
(4) key.
• Press the MODE (2) key to switch to the next setting step (seconds).
• Increase the target value for the seconds using the ST/STP (3) key or decrease it with the LIGHT
(4) key.
• Press the RESET (1) key to save the time target.
Use of the countdown timer
• Press the ST/STP (3) key to start the countdown timer.
• Press the ST/STP (3) key again to interrupt the countdown timer or to restart it.
• When the preset time has passed, an acoustic signal is emitted for approx. 60 seconds.
• Press any key to turn the acoustic signal off.
f) Alarm function
Activating or deactivating the alarm function
• Press the LIGHT (4) key to select the desired function (hour signal or alarm 1-5).
• To activate or deactivate the hour signal or the selected alarm, press the ST/STP (3) key. With
activated hour signal, a bell icon appears on the right top of the display. With activated alarm,
an alarm icon appears on the left top of the display.
• At the set alarm time an alarm sound is emitted for approx. 60 seconds. Press any key to turn the
alarm sound off.
Alarm time setting
• Select the alarm function to be set (alarm 1-5) using the LIGHT (4) key.
• Press the RESET (1) key to select the hour display.
• Increase the value of the hour display using the ST/STP (3) key or decrease it with the LIGHT (4)
key.
• Press the MODE (2) key to select minute display.
• Increase the value of the minute display using the ST/STP (3) key or decrease it with the LIGHT
(4) key.
• Press the RESET (1) key to save the setting.
g) Time of the second time zone
• Press the RESET (1) key to select the hour display.
• Increase the value of the hour display using the ST/STP (3) key or decrease it with the LIGHT (4)
key.
• Press the MODE (2) key to select minute display.
• Increase the value of the minute display using the ST/STP (3) key or decrease it with the LIGHT
(4) key. The minute display is changed in 30-minute steps.
• Press the RESET (1) key to save the setting.
Illumination
• Press the LIGHT (4) key to turn on the clock face light for a few seconds.
Battery Notes
• Batteries should be kept out of the reach of children.
• Do not leave batteries lying around in the open; there is a risk of them being swallowed by
children or pets. If they are swallowed, consult a doctor immediately.
• Leaking or damaged batteries can lead to caustic burning of the skin. Therefore, use suitable
protective gloves.
• Batteries must not be short-circuited, opened or thrown into a fire. There is a risk of explosion!
• Do not recharge normal, non-rechargeable batteries, due to risk of explosion! Only charge
rechargeable batteries that are intended for this purpose; use a suitable battery charger.
• Please pay attention to the correct polarity (plus/+ and minus/-) when inserting the battery.
Changing the Batteries
• If a battery symbol is shown on the left top of the display, the battery has to be replaced.
• Replacing the battery should be done by a specialist, using special clockmaker tools and profes-
sional knowledge.
• To replace the battery, the bottom of the casing is removed.
• The battery can then be removed from its holder and be replaced.
Water and Shock Resistance
In normal use, the wristwatch is protected against shocks. Nevertheless, do not expose the device
to extreme shocks such as it might occur if the device falls onto a hard surface. This might damage
the watch mechanism.
The labelling 10 ATM means that the watch is suitable for bathing, swimming, Snorkelling to 10 m
depth, car wash, showering and so on.
It is not a professional diver's watch. Never press the buttons under water.
Maintenance and cleaning
To clean the watch, a dry, soft, clean cloth is sufficient. For heavier soiling of the exterior, you can
moisten the cloth slightly with lukewarm water.
Clean the watch very carefully; otherwise you may scratch it.
Do not press too heavily on the glass cover, as this can lead to breakage.
After use in salt water the meter must be flushed with water.
Disposal
a) Product
Electronic devices are recyclable waste materials and must not be disposed of in the
household waste!
Dispose of an unserviceable product in accordance with the relevant statutory regula-
tions.
Remove the battery if there is one inserted and dispose of it separately from the product.
b) Normal and Rechargeable Batteries
As the end user, you are required by law (Battery Regulation) to return used batteries and re-
chargeable batteries. Do not dispose of used batteries in the household waste!
Batteries/rechargeable batteries contain harmful materials and are labelled with the
symbol shown to indicate that disposal in the household waste is forbidden. The sym-
bols of the relevant heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead (marking
can be seen on the battery/rechargeable battery, e.g. underneath the refuse bin symbol
shown on the left).
You can return your used batteries/rechargeable batteries free of charge at the official collection
points of your community, in our stores, or at places where batteries or rechargeable batteries
are sold!
You thereby fulfil your statutory obligations and contribute to the protection of the environment.
Technical data
Operating voltage.........................................3 V/DC
Battery ...........................................................1 x lithium coin cell CR2032
Battery life .....................................................approx. 2 years
Water-tightness ............................................10 ATM
Maximum diving depth ...................... .........10 m
Weight ............................................................80 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE.