TEMPERATURE CALIBRATION
The temperature can be calibrated with the function "F03" in the setup menu by setting a cor-
rection value.
CHANGING THE PASSWORD
• Select the setup menu (see "OPERATING FUNCTIONS" and then "Opening the setup
menu"). Enter the current password (factory setting: "111").
• If "F01" appears in the display, select the function "P01" with the buttons " " and " " and
press the button "
".
• Set the first digit of the password with the buttons " " and " " and press the "SET" button.
The display flashes shortly, if the value was changed.
• Select the function "P02" with the buttons " " and " " and press the button
"
".
• Set the second digit of the password with the buttons " " and " " and press the "SET" but-
ton. The display flashes shortly, if the value was changed.
• Select the function "P03" with the buttons " " and " " and press the button
"
".
• Set the third digit of the password with the buttons " " and " " and press the "SET" button.
The display flashes shortly, if the value was changed.
• Keep the "SET" button pressed until the current temperature is displayed again (approx. 3
seconds).
The new password is now saved.
RESETTING THE PASSWORD TO FACTORY SETTING
If you forgot your password, you can reset it to "111". Proceed as follows:
• Separate the temperature controller from the mains voltage.
• Keep both buttons "
" and "SET" pressed, and switch on the mains voltage. "ON" will
appear on the display.
• Release both buttons. The current temperature is shown in the display, the password is reset
to "111".
CLEANING
Dust can be very easily removed using a soft, clean, long-bristled brush and a vacuum
cleaner.
If you want to wipe the display, use a clean soft dry cloth. Do not use aggressive detergents, or
there might be changes in colour. Do not press the display too firmly. This may lead to scratch
marks and/or damage the display.
HANDLING
• Observe all safety and installation instructions in this manual.
• Do not expose the product to the following unfavourable ambient conditions at
the site of installation:
- Excessive humidity or damp
- Extreme cold (<-5°C) or heat (>+55°C), direct sunlight
- Dust or flammable gases, fumes or solvents
- Strong vibrations, impacts or blows,
- Strong magnetic fields such as those found in the vicinity of machinery or loud-
speakers
• Only operate the temperature controller when it is firmly assembled in an
enclosed casing.
• When assembling and operating the device, make sure the cable to the sensor
is not bent or jammed.
DISPOSAL
Please dispose of the device, when it is no longer of use, according to the current
statutory requirements.

TECHNICAL DATA

Operating voltage: ..............................200-240V~, 50-60Hz
Input: ....................................................<5W
Protection class: ..................................II
Sensor safety class: ............................IP68
Front plate safety class:........................IP54
Assembly dimensions (W x H): ............71 x 30mm
Dimensions of frontplate:......................75 x 34.5mm
Operating temperature: ........................-5°C - +55°C
Humidity during operation:....................10-95% rel. humidity, not condensing
Temperature range of sensor: ..............-50°C - +120°C
Accuracy : ............................................±0,5% (at -10°C to +85°C)
Resolution:............................................0.1°C (< 100°C)
Measuring rate: ....................................<= 2 seconds
Relay loading capacity: ........................max. 10A/240V
Impressum /legal notice in our operating instructions
These operating instructions are a publication by Voltcraft
®
, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7 (www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2009 by Voltcraft
®
±2% (< -10°C, > +85°C)
1°C (>= 100°C)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Etc-200

Inhaltsverzeichnis