Warning – risk of burns and fire
• The admissible ambient temperature range is -5 to +45°C. Do not operate the device outside of this
temperature range.
• Do not use the device near highly flammable materials. Always place the device at a location where
sufficient air circulation is ensured. Leave 50 cm of free space around the device. Never cover the air vents
of the housing.
Caution – material damage
• If the device has been exposed to drastic temperature fluctuation, do not switch it on immediately. The
resulting condensation may destroy the device. Allow the device to reach room temperature before
connecting it. Wait until the condensation has evaporated.
• Please use the original packaging to protect the device against vibration, dust and moisture during
transportation or storage.
• If a serial number label is affixed to the device, do not remove the label as this would make the guarantee
void.

SETUP

Output LEDs
Power input

Making the connections

1
Fix the controller at a suitable place with screws.
2
Connect the LED neon tube via the 4-pin power contact pin (accessory) to the cable at the OUTPUT
terminal. The load by the LEDs must not exceed 2 A per channel. The total load must not exceed 6 A;
otherwise the controller will be damaged.
3
Connect the controller via the mains cable to a grounded mains socket. Thus, the controller is switched
on.

Operation without DMX controller

For operation without DMX controller control programs are provided, which can be adjusted via the DIP
switches.
1
Set DIP switch 10 to the lower position (ON) to enable operation without DMX controller.
2
If DIP switch 9 is set to the upper position (OFF), you can select color change programs.
Switch
Program
1-4
Running speed
5-6
Color change
7-8
Color fade
⊳ Position of switch 10 for operation without DMX controller
12/16
DIP switches
DMX input
DMX output