1. Prior to assembling the insert
Chimney Draught
Air Supply
Flooring under Fireplace
2. Technical Information
3. Distance to combustible material
4. Assembly
Connection of the flue
Operational control
Painting the surround
5. Lighting the fire for the first time
6. Maintenance
Cleaning and inspection
Ashes
Thermotte®/Vermiculite Plates
Door and glass
7. Warranty
8. Advice on lighting a fire
Some advice in case of combustion problems
EC CONFORMITY DECLARATION
Date of issue: 15.09.2009
Conformity declaration issued by:
Company name:
Address:
Postal:
Country:
Phone:
Fax:
Web:
E-mail:
Identification:
Product type:
Insert type:
Fuel type:
Flue gas temperature:
CO content at 13 % O
:
2
Thermal output, nominal value:
Energy efficiency:
Safety measurements:
Minimum distance to adjacent
combustible materials:
Country
Classifications
EUR
Intermittel
General manager, Nordpeis AS
10
10
Nordpeis AS
Gjellebekkstubben 9/11
N-3420 Lierskogen
Norway
(+47) 32 24 47 00
(+47) 32 24 47 11
www.nordpeis.no
post@nordpeis.no
Nordpeis N-36V
Fireplace insert
Steel fireplace insert burning solid fuel
firewood only - see manual
280 ºC
0,09 %
7,0 kW
80,7 %
Only to be used in non-combustible surrounds.
Must be used in accordance with user manual.
Must be placed in accordance with user manual.
Test standard
Approved by
EN 13229
RRF
Stian Varre
Rapport Nr. RRF - 29 09 1918
Inspection code: 1625
Rhein-Ruhr Feuerstättenprüfstelle GmbH
Am Technologiepark 1, D-45307 Essen
1. Prior to assembling the insert
10
Our surrounds are all made of non-combustible
10
materials. All our inserts/stoves are tested according
to the latest European requirements and also to the
10
11
Norwegian SINTEF standard, which includes particle
tests. Several European countries however have
11
individual rules for installation of inserts, stoves and
11
fireplaces.
11
The client is entirely responsible for the fulfilling of
12
these local rules concerning the installation in his
12
region/country. Nordpeis (Northstar) is not responsible
12
regarding correct installation. You should check local
regulations concerning: distance from firebox to
12
combustible/flammable materials, insulation materials/
12
requirements between fireplace surround and back
12
wall, size of floor plates in front of fireplace/stove if
13
required, fluepipe connection between firebox and
13
chimney and insulation requirements if fluepipe goes
13
through inflammable wall such as a wooden wall.
13
For your own safety, comply with the user
manual. All safety distances are minimum
14
distances. Installation of the insert must
15
comply with the rules and regulations of the
country where installed. Nordpeis AS is not
responsible for wrongly assembled inserts.
Chimney Draught
Compared with older models, the clean burning
inserts of today put significantly higher demands
on the chimney. Even the best insert will not work
properly if the chimney does not have the right
dimensions or is not in good working order. The
draught is mainly controlled by gas temperature,
outside temperature, air supply as well as the height
and inner diameter of the chimney. The diameter of
the chimney should never be less than that of the flue/
chimney collar. At nominal effect there should be a
negative pressure of 18 to 25 Pascal.
The draught increases when:
The chimney becomes warmer than the outside air
The active length of the chimney is increased (over
the hearth)
Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large in relationship to
the fireplace, as the chimney does not heat up well
enough. If possible, insert a smaller chimney pipe.
Draught that is too strong can also be controlled with
a damper.
Air Supply
A set for fresh air supply is available as an accessory,
and will ensure that ventilation systems, kitchen fans
and other factors that can create a downdraught in the
room of the fireplace affect less the air supply to the
insert. Insufficient air supply can cause downdraught
and thereby low combustion efficiency and the problems
that this entails: soot stains on the glass, inefficient
use of the wood and a soot deposits in the chimney.