Failure: The water level in the aquarium rises too
high in the course of the time.
Cause: Protective grid clogged with plant debris,
algae or dirt.
Remedy: Remove the protective grid in regular
intervals, and use a brush or vinegar to
thoroughly clean.
Cause: Air has gather in the U-shaped tube; the
water volume is below 300 l/h (79.2 USgal./h).
Remedy: Increase the water volume at the
recirculation pump; the U-shaped tube needs
a minimum capacity to be able to remove air
bubbles automatically.
Cause: The silicone hose is not installed properly
well or the hose end is clogged completely.
Remedy: Check the silicone hose; the hose end
should be immerged in the outlet chamber.
Cause: The outlet hose is constricted due to
clogging.
Remedy: Check the outlet hose, and clean, if and
when necessary.
Disfonctionnement: Le niveau d'eau dans
l'aquarium augmente au fil du temps.
Raison : Grille d'aspiration obstruée par des
plantes, des algues ou des dépôts divers.
Solution : Retirez régulièrement la grille d'aspiration
pour un nettoyage avec brosse et vinaigre.
Raison : Accumulation de bulles d'air dans le siphon
en U, débit de circulation inférieur à 300l/h.
Solution : Augmentez le débit de la pompe de
reprise, le siphon en U nécessite un débit
minimal afin de pouvoir évacuer les bulles d'air.
Raison : Le tuyau silicone n'est pas bien inséré ou
l'extrémité n'est pas parfaitement obstruée.
Solution : Vérifiez le tuyau silicone, son extrémité
doit être immergée dans une des chambres.
Raison : Tuyau d'évacuation obstrué.
Solution: Vérifiez ou nettoyez le tuyau d'évacuation.