Secondary_value_2
Abb. 30: Abgleich VEGABAR 65
Parameterliste
Die folgende Liste enthält die wichtigsten Parameter und ihre Bedeutung:
primary_value
l
Process Value after min/max-adjustment and linearization. Selected as input to AIFB by setting
-
'Channel' = 1. Unit derives from 'Primary_value_unit'
primary_value_unit
l
Unit code of 'Primary_value'
-
%
-
secondary_value_1
l
Process pressure. Selected as input to AIFB by setting 'Channel' = 2. Unit derives from
-
'Secondary_value_1_unit'
secondary_value_1_unit
l
Unit code of 'Secondary_value_1'
-
bar, PSI, ..., m, ft, ...; in case of length type engineering unit and access to parameters the
-
corresponding values will be converted by density factor
secondary_value_2
l
Value after min/max-adjustment. Selected as input to AIFB by setting 'Channel' = 3. Unit derives
-
from 'Secondary_value_2_unit'
secondary_value_2_unit
l
Selected unit code for "secondary_value_2"
-
sensor_value
l
Raw sensor value, i.e. the uncalibrated measurement value from the sensor. Unit derives from
-
'Sensor_range.unit'
VEGABAR 65 • Foundation Fieldbus
100 %
0 %
scale_in_0
scale_in_0
0
%
-0,500
scale_in_100
Sensor_value
scale_in_100
100
0,500
bar