• The appliance must have the electrical installation which lets you disconnect the appli-
ance from the mains at all poles with a contact opening width of minimum 3 mm.
• If the fixing bracket is near to the terminal block, always make sure the connection cable
does not come in contact with the edge of the bracket.
• You must have correct isolation devices: line protecting cut-outs, fuses (screw type fuses
removed from the holder), ground leakage trips and contactors.

Disposal of the appliance

• To prevent the risk of physical injury or damage
– Disconnect the appliance from the power supply.
– Cut off the mains cable where it connects with the appliance and discard it.
– Flat the external gas pipes if there are fitted.
– Speak to your local authorised facilities for disposal of your appliance.

INSTALLATION

WARNING!
The following instructions about installation, connection and maintenance must be carried
out by qualified personnel in compliance with standards and local regulations in force.

Gas Connection

It is necessary that the connection to the gas mains are carried out by means of an AGB
tap. Choose fixed connections or use a flexible pipe in AGB (stainless steel) in compliance
with the regulation in force. If you use flexible metallic pipes, be careful they do not come
in touch with mobile parts or they are not squeezed. Also be careful when the hob is put
together with an oven.
The connection must be done according to regulation NBN D 5I.003.