inflammable material, for instance ceramic, stone, glass or steel etc. (dimensions according to the local
regulations).
The base must extend at least 50 cm at the front and at least 30 cm at the sides, in addition to the
opening of the loading door (Picture 2 B).
d)
no flammable components (e.g. wall units) must be present above the product.
e)
If the stove is installed on a wall made of flammable material, it is necessary to replace that part of the wall
with a non-flammable material layer, for instance ceramic, stone, glass or steel etc. The replaced part of wall
must be as large as the stove is and, starting from the floor, protrude around 100 cm at least (Picture 2 C) from
the top side of the stove.
The product must work exclusively with inserted ash drawer.
Solid combustion residuals (ashes) must be collected in an air-tight and fire-resistant container. The appliance must
never be switched on when there are gaseous emissions or vapours (for example glue for linoleum, gasoline etc.). Do
not deposit flammable materials close to the same.
During the combustion will be spread thermal energy which warms up the surfaces, the door, the fireplace glass, the
handles and knobs, the smoke pipe and the front side of the stove. Please avoid the contact of these parts without
gloves or the relevant tools.
Warn children of the danger and keep them away during the operation of the stove.
The use of a wrong or wet fuel causes the formation of creosote deposits in the flue and will fuel a chimney fire.

4.1. FIRST-AID MEASURES

Should any fire arise in the stack or in the flue:
a) Close the feeding door and the ash drawer door.
b) Close the registers of combustion air
c) Extinguish the fire using carbon dioxide fire-fighting means (CO
d) Seek immediate intervention of FIRE BRIGADE.
DO NOT EXTINGUISH FIRE USING WATER JETS
When the fire has been extinguished, let the flue check by an expert to find possible cracks and permeable points.
5.

FLUE

Essential requirements for a correct operation of the device:
the internal section must be preferably circular;
be thermally insulated and water-proof and produced with materials suitable to resist to heat,
combustion products and possible condensates;
not be throttled and show a vertical arrangement with deviations not greater than 45° ;
if already used, it must be clean;
observe the technical data of the instructions manual;
18
30
A
30
B
2
dust).
7193750 Rev.03 – EN