When the carbon is worn to 6 mm in length or if the
spring or shunt wire is burned or damaged, replace both
brushes. If the brushes are found serviceable after remov-
ing, reinstall them.
m Electrical connection
The installed electric motor is completely wired ready for
operation.
The customer's connection to the power supply system, and
any extension cables that may be used, must conform with
local regulations.
Important remark:
The motor is automatically switched off in the event of
an overload. The motor can be switched on again after a
cooling down period that can vary.
Defective electrical connection cables
Electrical connection cables often suffer insulation dam-
age.
Possible causes are:
Pinch points when connection cables are run through
window or door gaps.
Kinks resulting from incorrect attachment or laying of
the connection cable.
Cuts resulting from running over the connecting cable.
Insulation damage resulting from forcefully pulling out
of the wall socket.
Cracks through aging of insulation.
Such defective electrical connection cables must not be
used as the insulation damage makes them extremely
hazardous.
Check electrical connection cables regularly for damage.
Make sure the cable is disconnected from the mains
when checking.
Electrical connection cables must comply with the regula-
tions applicable in your country.
Single-phase motor
The mains voltage must coincide with the voltage spec-
ified on the motor's rating plate.
Extension cables up to a length of 25 m must have a
cross-section of 1.5 mm2, and beyond 25 m at least
2.5 mm2.
The connection to the mains must be protected with a
16 A slow-acting fuse.
Only a qualified electrician is permitted to connect the
machine and complete repairs on its electrical equip-
ment.
In the event of enquiries please specify the following
data:
Motor manufacturer
Type of current of the motor
Data recorded on the machine's rating plate
Data recorded on the switch's rating plate
If a motor has to be returned, it must always be dis-
patched with the complete driving unit and switch.