Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Prohibited Areas Of Application - Rowi HHL 2000 Flat Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Thermal fuse
A thermal fuse is provided as an extra safety precaution. If this triggers and opens the elec-
tric circuit, the cause of this is an abnormal overheating in the appliance. In this case, the
appliance must be repaired by a specialist to ensure continued safe heating. Please contact
the ROWI Service Team to replace defective parts and install a new fuse.
IP degree of protection
P The appliance corresponds to degree of protection IPX0. Appliances of this category
are not protected against penetration by foreign bodies or water.
P Only operate these appliances in an upright position.
1.5

Technical data

Power supply
Max. heat output
Heating stages
Room heating capacity
Degree of protection
Protection class
Setup dimensions (L x W x H)
Product weight
Tab. 1: Technical data
1.6

Prohibited areas of application

P This appliance may not come into contact with water or moisture either during operation
or during storage.
P This appliance is only designed for household use. Do not use this appliance for com-
mercial purposes or in the open air.
P The appliance may not be used for wall and ceiling installation.
(assuming a room height of 2.4 m)
29/40
230 V~50 Hz
2000 W
2 stages (1000 W/2000 W)
approx. 60 m³
IPX0
II
24.0 x 24.5 x 11.5 cm
0.9 kg
GB

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hhl2003 flatHhl 2001 flat