Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated. Plug the terminator with a 120
between Signal (–) and Signal (+) in the DMX-output of the last fixture.

Connection between devices

On the rear panel, there is an IEC socket (Power Out). Connect the output with the input of the next fixture
until all fixtures are connected.

Master/Slave operation

The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the LED CLS-18 QCL RGBW 18x8W you can find an XLR-jack and an XLR-plug, which
can be used for connecting several devices.
Choose the device which is to control the effects. Set the desired Master mode on the master device. This
device then works as master device and controls all other slave devices, which are to be connected to the
master device via a balanced microphone lead. Set the DMX start address 001 on every slave device.
Connect the DMX OUT-jack with the DMX IN-plug of the next device.

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
Please note: A maximum of 8 EUROLITE LED CLS-18 QCL RGBW 18x8W may be linked together. After
every 8 devices, the fixtures must have a renewed connection with the power mains.

OPERATION

After you connected the spot to the mains, the EUROLITE LED CLS-18 QCL RGBW 18x8W starts running.
The LED display lights up and you can choose the desired mode via the buttons MODE, ENTER, UP,
DOWN.