Technical Data

The following table lists input values for the appliance.
Burner
MAIN
BACK
SIDE
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Gas Category
Orifice Sizes (see
above)
Gases / Pressures
Countries
Do not tamper with or modify regulator. Use only regulators, which supply the pressure, listed in the table
above. A regulator of 28-30mbar must be used for butane or a 37mbar regulator for propane. For grills
set up to operate at 50mbar, the grill is equipped with an internal regulator. This internal regulator has an
outlet pressure of 30mbar and must not be modified or adjusted. For replacement, use only the regulator
specified by the manufacturer: Maxitrol model number RV47LSMF.
This unit includes an internal regulator which stabilizes the gas pressure and improves grill performance.
This regulator cannot be adjusted. There is a pressure tap located on the side of the regulator. It can
be used by a qualified service person when servicing the grill to determine if the regulator is functioning
properly. The screw within the pressure tap must always be kept tight, except when performing a pressure
test on the regulator (qualified service personnel only).
Leak Testing Instructions
WARNING!
part of the gas system is replaced.
WARNING!
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak
Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solutions department and have the grill inspected by a certified
gas installer.
STOP
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill
inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
N415-0275CE-GB-DE OCT 23.17
Orifice Size
(Gross) Heat Input (Total)
I
58 (1.07mm)
64 (0.91mm)
60 (1.02mm)
I3B/P(30)
I
Butane 30mbar
Propane 30mbar
BE, BG, CY, DK, EE, FI,
FR, GB, HR, HU, IS, IT,
LT, LU, MT, NL, NO,
RO, SE, SI, SK, TR
A leak test must be performed annually and each time a cylinder is hooked up or if a
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
Gas Usage (Total)
14.4 kW
4.0 kW
3.8 kW
I3+(28-30/37)
I3B/P(50)
I
II
Butane 28-30mbar
Butane 50mbar
Propane 37mbar
Propane 50mbar
BE, CH, CY, CZ, ES,
AT, CH, DE, SK
FR, GB, GR, IE, IT, LT,
LU, LV, PT, SK, SI
5
EN
1047 g/h
291 g/h
275 g/h
www.napoleongrills.com