Addressing the device

Set DIP switch 10 to ON.
Dip switches 1 - 9 set the DMX address.
Each device occupies 2 channels. To ensure that the control signals are properly directed to each device,
the device requires addressing. This is to be adjusted for every single device by changing the DIP-switches
as set out in the table below.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX data link. If two, three or more devices are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:
Setting the DMX-
DIP-switch no.
starting address:
Projector number
DMX-starting
& channels
address
Device 1 - channels 1-2
Device 2 - channels 3-4
Device 3 - channels 5-6
Device 4 - channels 7-8
Device 5 - channels 9-10
Controlling:
After having addressed all LED FLD-252 UV 10mm Floods, you may now start operating these via your
lighting controller.

DMX-protocol

Channel
DMX Value Function
1
0-255
0-10
2
11-20
21-255

Blackout

In order to select Blackout, set DIP switch 10 to ON and DIP switches 1 to 9 to OFF.
1
2
3
4
1
2
4
8
On
Off
Off
On
Off
On
Off
On
Off
On
Off
Dimmer
Blackout
Full ON (dimmable via CH1)
Strobe with increasing speed
5
6
7
8
9
16
32
64 128 256
%
0-100
100
100
0-100