Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The controls of the receiver are located on the back of the equipment.
LSA/LSB 600, LSA 667
1) 5 mm LED red
This LED displays switching condition and short circuit protection.
2) 3 mm Duo LED red/green
This LED displays contamination and transmitter light signal level 1
3) 3 mm LED green
This LED displays transmitter light signal level 2
4) Connecting cable or plug, 3/4" thread.

6.3 LED Display

Transmitter
LED
GREEN
Receiver
LED 1
RED
LED 1
FLASHING RED
LED 1
DARK
LED 2
FLASHING RED
LED 2
FLASHING GREEN
TO
LED 2
GREEN
LED 3
FLASHING GREEN
TO
LED 3
GREEN
21
EQUIPMENT IS READY FOR OPERATION
NO SIGNAL COMING FROM TRANSMITTER
(O
IS RECEIVED
BJECT DETECTION
OVERLOAD ON THE OUTPUT
S
IGNAL COMING FROM THE SENDER
(
O
IS RECEIVED
NO
BJECT BETWEEN
TRANSMITTER AND RECEIVER
A MINIMUM AMOUNT OF SIGNAL COMING FROM
TRANSMITTER IS RECEIVED
ENOUGH SIGNAL COMING FROM TRANSMITTER IS
;
RECEIVED
LED FLASHES MORE FREQUENTLY AS THE
TRANSMITTER SIGNAL INCREASES
A STRONG SIGNAL COMING FROM TRANSMITTER
;
IS RECEIVED
LED FLASHES MORE FREQUENTLY AS THE
TRANSMITTER SIGNAL INCREASES
LSD 600
)
)
(
)
CONTAMINATION

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis