Chain motor CDi EasyDrive/2

Manually set formation

Automatic detection and set formation of
drives (without PC connection)
Notes: The drives are configured as single
drives (default).
1. To automatically detect and set formation a 24V DC power
in UP direction ▲ must be applied in accordance with the
electrical connection (for example, an OPEN command
via a vent switch).
2. The drives goes up.
3. Place a jumper wire for about 1 second between contacts 1
(24 V) and 3 (Bus A).
4. The drives stoped, if they went before.
5. Remove the jumper again.
6. The drives goes short UP.
7. Subsequently the drives retracts and make a
zero crossing.
8. The drives run per participant 1 cm OPEN.
9. All connected drives are now recognized.
Resetting the drive to factory settings
(Single drives)
1. Remove the connection cable.
Then provide the individual drive with 24 V DC voltage in
the UP direction ▲ (for example, an OPEN command
via a vent switch).
2. Place a jumper wire for about 1 second between contacts 1
(24 V) and 3 (Bus A).
3. The drive stop if he went before.
4. Remove the jumper again.
5. The drive go short UP.
6 Subsequently the drive retract and make a
zero crossing.
7. The drive is reconfigured as a single drive.
8. Perform the same process on other drives.
1)
The actuators only drives if they a) are configured as a single or b) are already known today.
24
1)
drive 2
M
=
drive 1
M
=
on-site junction
1 2 3 4 5 6
box with
connecting
terminals
jumper
power cable on site
drive 1
M
=
on-site junction
1 2 3 4 5 6
box with
connecting
terminals
M
=
jumper
power cable on site
connection cable
power cable
1: 24 V 0 V
2: 0 V 24 V
3: Bus A
4: Bus B
5: signal contact
6: signal contact
power cable
1: 24 V 0 V
2: 0 V 24 V
1
3: Bus A
2
4: Bus B
3
M
5: signal contact
4
6: signal contact
=
5
6