18.
Menu
Menu
In the "Menu" setting one can activate a number of functions. To activate the
function you must first light up the lower row of functions (see item 12).
To step between the various functions, use the arrow keys.
OFFSET
(Temperature adjustment)
With this function you can calibrate
the temperature on the panel if you
notice that the temperature (the
stabilised room temperature) does
not correspond with the temperature
shown on the panel.
1.
Press the button with the arrow
until the Menu symbol flashes.
Press +On.
PUMP 12V/PUMP AU.
The12V pump is used in the PU 12
setting even if 230V is connected. In
the PU AU position, the 230V pump
works, and when 230V is discon-
nected, the 12V pump starts. The PU
AU function is activated in the factory
setting.
1.
Press the button with the arrow
until the Menu symbol flashes.
Press +On.
SERVICE
With this function one can see
what values* from the heater are
displayed. The values are updated
once per second.
1.
Press the button with the arrow
until the Menu symbol flashes.
Press +On.
* The values shown during service are:
FA (revolutions): The speed of the fan divided by 2.
SH (temp): Warm water temperature.
HE (temp): Operating temperature.
OH: If the overheating protection has been tripped On or
alternatively Off.
HS (X): Software version in the heater.
PS (X): Software version on the panel.

Button sound

With this function you can connect or
disconnect the button sound to the
buttons. The button sound is discon-
nected in the factory setting.
1.
Press the button with the arrow
until the Menu symbol flashes.
Press +On.
2.
When OF is displayed, adjust the
temperature displacement with +/
On or -/Off (+/-5°C in intervals of
0.5°C).
blinkar
flashes
2.
When OF is displayed, step with
the arrow key until PU AU is
displayed. Press +/On and PU
12 is displayed.
flashes
blinkar
2.
When OF is displayed, step with
the arrow key until SE is dis-
played.Press +/On to see the
various values (-/Off can also be
used).
blinkar
flashes
I: Amp. Guideline value shown in steps of 0.5 A.
WI: Window breaker on-off.
ES: External start on-off.
10-RS: Heater information, only for ALDE.
2.
When OF is displayed, step
with the arrow key until Sn is
displayed. Press +/On and the
button sound is connected.
blinkar
flashes
3.
Press Store to leave the OFF-
SET function.
flashes
blinkar
3.
Press -/Off and PU AU is dis-
played. Press Store to leave the
pump function.
flashes
blinkar
3.
To leave Service, press Store.
blinkar
flashes
3.
Press -/Off to disconnect the
button sound. Then press
Store to leave the button
sound function.
blinkar
flashes
19