WEIGH METHODS

Select "Lock On" for animal weighing. Use "General" for general weighing.
General Weigh Method
All purpose weigh method for weighing stable loads. It does not "Lock On" the weight.
Lock-on Weigh Method
Weighs active animals and displays stable accurate weight. Lock-On sensitivity is adjusted using
"LOCKON" menu (See Pg Fout! Bladwijzer niet gedefinieerd.).
Scale "Locks-On" to weight.
Weight is displayed stable, even if motion never stops.
Small „L‟ appears on left side of display indicating weight is "Locked-On".
Animal‟s weight must be greater than 0.67% of scales "capacity" (CAP) before system can
"Lock-On".
Example: If "CAP" = 4000, 27 or more is required for scale to lock-on.
Note:
Use a weight value for Zero Tracking (ZTRACK) that is less than 0.67% of capacity.
To break lock, add or remove WEIGHT FROM SCALE PLATFORM. The default setting is 50%.
The weight value that is used to "break the lock" and return to normal weighing can be selected
by choosing a value from 01 to 99%. (See Pg Fout! Bladwijzer niet gedefinieerd.) For
example, if unlock is set to 10(%) and weight is locked at 1000, display will "unlock" and return to
normal weighing at 900, once 10% (100) is removed.
"Locked-On" weight can be "rechecked", press
weight.
. this breaks "lock" and scale recalculates