Herunterladen Inhalt Inhalt Diese Seite drucken

Fitting Check / Function Test; Maintenance Work; Technical Data - STG-BEIKIRCH M3/...-500N:250N/LA/AC Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Linear drive M3/...-500N:250N/LA/AC

Fitting check / Function test

When fitting has been carried out: Check the drives by test running twice.
When doing so, pay exact attention to windows and drives.
Drives must run at right angles to the window.
Drives must not hit the structure in any position or come into contact with it.

Maintenance work

If the equipment is used in ventilation systems it is recommended to check, maintain and if necessary repair them once a
year.
Remove soiling from the equipment. Check the fastening and clamping screws for a tight fit. Test the equipment using a
test run. The motor drive is maintenance free. Faulty equipment may only be repaired in our works. Only original spare
parts are to be used. Check the equipment is ready to run on a regular basis. A maintenance contract is recommended
to cover this.

Technical data

Input and operating voltage:
Current draw (nominal):
Pressing force:
Tractive force:
Nominal clamping force:
Stroke lengths:
Power supply cable:
Cut-off:
Speed:
Start-up time:
Protection degree:
Totally insulated:
Ambient operating temperature:
Dimensions:
Housing:
End caps:
Colour (standard):
Special colour:
Service life:
Potential free contact:
When dimensioning the power supply and the cable cross-sections for the supply lines to the motors as a function of the
control panels used, the increased currents associated with start-up toques must be taken into account!
Trouble-free and safe operation is only warranted when used in conjunction with an appropriate manufacturers control
unit. Request a technical conformity declaration from the manufacturer of an alternative control unit to ensure trouble-free
and safe operation.
18
230 V AC / 50 Hz (+10 % / -15 %)
approx. 200 mA
max. 500 N
max. 250 N
2000 N
82, 300, 500 and 750 mm, further lengths available
5 x 0.75 mm², length approx. 1.60 m, color grey
integrated external electronic power cut-off
approx. 10 mm/sec
3 Min. (ED/ON), 7 Min. (AD/OFF)
IP 54 according to DIN EN 60529
class II according to DIN 40 014
-5° C to +75° C
41 x 82.5 x stroke + approx. 133 mm (w x h x length)
rectangular aluminium profile
grey plastic
EV1/silver anodized
RAL-colour patterns on request
>10,000 ventilation cycles at nominal load
indicates „not closed"
04/24999913