Herunterladen Inhalt Inhalt Diese Seite drucken

patura P6000 Bedienungsanleitung Seite 59

Vorschau ausblenden Andere Handbücher für P6000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Battery selection
As a guide, the recommended battery size in amp hour (Ah) required for each energiser
model is shown below. This table is based on a 7 day operating period between battery
charging. Although operating time can exceed 7 days, this is likely to cause battery damage
and will necessitate frequent replacement of the battery.
For best system reliability and long term battery life, the preferred battery and charging
regime is to use a deep-cycle, lead-acid battery and to recharge it when it is half discharged.
For more information see "Battery Test setting" on page 57.
Selector switch position
Battery test
Slow Speed – Day
Fast Speed - Night
Fast Speed - Day
Slow Speed - Night
Half power
Full power
Warning! 12 V rechargeable lead-acid batteries must be used.
Battery management
Warning! Batteries contain harmful chemicals and when used incorrectly, may cause injury.
Observe the guidelines for battery care, maintenance and safety in the documentation
supplied with your battery.
Battery charging
Warning!
Do not attempt to recharge a non-rechargeable battery.
When recharging a battery, ensure that there is adequate ventilation to allow gases to disperse.
Regular recharging of the battery is essential. Use a suitable safety approved battery charger
and refer to the battery manufacturer's recommendations.
1. Disconnect the battery from the energiser.
2. Attach the positive (+) battery charger lead to the positive terminal of the battery, and the
negative (–) battery charger lead to the negative terminal on the battery.
3.
Connect the battery charger's input power plug to a mains or line socket and turn on the power supply
4. After the battery is charged, disconnect it from the battery charger before connecting it to
the energiser.
Current required
P4500/P4600
410 mA
750 mA
530 mA*
1000 mA*
*(24 hours average)
530 mA*
1000 mA*
*(24 hours average)
330 mA
650 mA
1250 mA
- 59 -
P6000
P4500/P4600
150 Ah
190 Ah
190 Ah
630 mA
120 Ah
230 Ah
Battery capacity
P6000
230 Ah
300 Ah
300 Ah
200 Ah
360 Ah
.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

P4500P4600

Inhaltsverzeichnis