Using the power adaptor and battery leads
The energiser is supplied with a power adaptor (for connection to mains/line power) and a set
of battery leads (for connection to a battery). Before connecting a power adaptor or battery
leads, ensure the energiser selector switch is set to "
To use the power adaptor:
1. Connect the power adaptor to the Power input socket on the rear of the energiser. Observe
the correct polarity.
2. Connect the power adaptor to a suitable mains/line power socket, ensuring there is
25 mm (1") of clear space around the power adaptor.
To remove the power adaptor:
1. Disconnect the power adaptor from the mains/line power.
2. Carefully pull the plug from the rear of the energiser by wiggling it gently.
To use the battery leads:
1. Insert the battery lead into the Power input socket on the rear of the energiser. Observe the
correct polarity.
2. Attach the red clip to the positive (+) terminal of the battery and the black clip to its
negative (-) terminal
Note: If the energiser is to be used as part of a permanent outdoor installation such as a
solar installation, the battery lead clips should be replaced by permanent battery connectors.
To remove the battery leads:
1. Remove the clips from the battery terminals.
2. Hold the battery lead by the rubber sleeve and carefully pull it from the rear of the
energiser by wiggling it gently.
Installing the energiser indoors
The energiser must be installed indoors when being powered by mains/line power.
Warning!
• Do not use a mains/line power extension lead.
• Allow 25 mm of clear space around the mains/line
power adaptor.
To install the energiser indoors:
1. Select a suitable installation site. See "Selecting a
site for the installation of the energiser" on page 51.
2. Mount the energiser on a wall. Use the template prin
-ted on the back cover of this manual, if required.
3. Connect the Fence earth terminal (green) to the ener
giser earth system.
OFF
".
25 mm
clear space
- 52 -
Insulated
high-voltage
cable
1.7 m
Earth system