"Basic set-up" sub-menu (
)
!
If at all possible, pre-programmed values should
not be changed because if they are the contrast in
all the channel positions will change with this con-
trast setting.
1
1
Press the
.
button followed by the numeric button
.
– The main menu appears followed by the "Basic
set-up" sub-menu.
/
1
1
30
2
44
)
X
2
/ OK
Decoder norm selection ( / 1)
1
You can choose between the following decoder set-
1
tings:
1
normal (FBAS)
2
2
PAL (deemphasis)
3
linear base band
4
MAC (for D2MAC decoders)
3
For more detailed information please see the opera-
ting manual for the decoder.
Pre-setting contrast levels 1 and 2
1
Choose rows » 1
30« and then » 2
44«.
2
In exceptional cases you can change the values of
the " 1« and » 2" contrast levels between "O"
and "64".
4
– this setting should be made so as to give the best
sound and image quality.
)
Blocking the receiver (
)
You can block your receiver to prevent unauthori-
zed use.
) )
Select row
X.
x
c
You can block the receiver using the
and
but-
tons.
)
Receiver block "on":
»
«
)
Receiver block "off":
»
If you block your receiver and then switch into
stand-by mode virtually all of the operating func-
tions and all of the menus will be blocked.
The receiver can only be unblocked by keying in the
correct combination of buttons on the remote con-
trol.
O
Press the
button to save all settings.
– The main menu appears on the screen again.
When the receiver is blocked
If you lock the receiver and then switch to stand-by,
the following will appear on screen:
) )
. . . .
»
«
.
Each dot (
) represents a button on the remote con-
trol. After each button has been pressed the dot
-
will be replaced with a short line (
).
Press the following buttons consecutively on the
remote control
c x
| ] .
Once the correct sequence has been entered the
receiver will be unblocked. Switching the receiver
into stand-by mode will block it again.
While the receiver is switched on, it can be
unblocked at any time using the "Basic set-up" sub-
menu (settings )
X).
O
Use the
button to save all settings.
– the main menu reappears on the screen.
"LNC settings" sub-menu ($)
Press the
.
button followed by numeric button
.
1
– the main menu appears followed by the "LNC set-
tings" sub-menu
– "2" will be flashing (the number of the selected
LNC arrangement).
$
1
A
09 . 750 GHZ
~
$
2
A
1
09 . 750 GHZ
$ %
/ OK
1
Key to symbols:
2
$
2
LNC arrangement (LNC type, see
page 14).
A1 09.750 GHZ Satellite A selected
LO frequency of LNC without 22 kHz
3
switching signals.
~
A1 09.750 GHZ Satellite A selected
LO frequency of LNC with 22 kHz
switching signals.
$
%
LNC voltage supply
on ( ) off (X).
exit menu.
O
save and exit menu.
LNC arrangements ($)
1
In order to tune the receiver as finely as possible to
the various aerial installations, 6 LNC arrangements
are available for the SAT input.
Depending on the LNC arrangement selected, vary-
ing switching signals are emitted when changing to
2
other channel positions (22 kHz, mini DiSEqC,
DiSEqC 1.0) in order to select the LNC required for
reception and its frequency range.
The oscillator frequency of the LNC used must be
entered. The number of possible oscillator frequen-
cies will depend on the LNC arrangement chosen.
The different variations in the 6 LNC arrangements
are shown on pages 14 and 15.
LNC oscillator frequencies ($)
The receiver is pre-programmed for the following
LNC oscillator frequencies:
A1
22 KHz off:
09 . 750 GHZ
~
A1
22 KHz on:
09 . 750 GHZ
22 KHz off:
09 . 750 GHZ
B1
~
22 KHz on:
09 . 750 GHZ
B1
22 KHz off:
09 . 750 GHZ
A2
~
22 KHz on:
09 . 750 GHZ
A2
B2
22 KHz off:
09 . 750 GHZ
~
B2
22 KHz on:
09 . 750 GHZ
These can be changed if you use an LNC with a dif-
ferent oscillator frequency.
x
c
The
and
buttons can be used to change the
values step by step. The values can also be entered
directly by using the numeric buttons
... .
Use the ] and | buttons to select the row you
want to change and enter the "new" value of the
oscillator frequency.
If you are using a number of LNCs, all the oscillator
frequencies will need to be checked and, if neces-
sary, "re-entered".
LNC voltage supply – to switch on/off
($ % )
The LNC voltage supply is switched on as a factory
setting. The receiver supplies power to the satellite
aerial.
If your receiver is connected together with other
satellite receivers to a joint aerial (a so-called single
cable solution in the master distribution), you will
need to switch off the LNC voltage supply
$ %
X«) otherwise the »
$ %
« setting is retai-
ned.
O
Press the
button to save the settings.
– The main menu appears on the screen again.
Please read the following pages!