Herunterladen Inhalt Inhalt Diese Seite drucken

perrot P2S Bedienungsanleitung Seite 17

Vorschau ausblenden Andere Handbücher für P2S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.2
Clean filter for control water
The drive of the sprinkler takes place with help of a cylinder. The control water is
pre-cleaned by means of the filter. The cleaning interval has to be fixed in
dependence of the level of the pollution and operating time.
Please use brush and high pressure cleaner for cleaning the filter.
6.3
Clean piston drive and piston drive area
In case that the drive doesn't function because of much dirt, the piston drive has to
be removed and cleaned.
6.3.1 Remove piston drive: (see TDP055e-rep)
TDP057d+e.doc
Perrot REGNERBAU CALW GmbH
Rev. 22.10.2010
Industriestraße 19-29 / D-75382 Althengstett / Germany
Telefon : 0049-7051-162-0 / Fax : 0049-7051-162–133
E-mail :perrot@perrot.de / E-mail Konstruktion : technik@perrot.de
Filter for
control water
Seite / Page 17 / 20