Servicing / disassembly

Thoroughly clean the pump and the drive assembly
in regular intervals, at least once a year. In case of
unfavourable conditions, such as high lime content,
excessive debris, or pump failure, shorter intervals
may be necessary.
Remove the intake strainer (1).
Turn the housing locking bar counter-clockwise and
remove (2).
Remove the impeller cover (3) and take out the
drive unit (4).
If the drive unit cannot be removed due to liming or
dried debris, do not use force ! Place the pump or
drive unit in a diluted vinegar or citric acid solution
for about 24 hours.
DO NOT USE STRONG ACIDS! If the drive unit still
cannot be removed, contact your Tunze distributor
for repair service.
Entretien / Démontage
Nettoyez régulièrement la pompe et l'entraînement
de la pompe, au moins 1 x par an. Lors de conditions
d'utilisation sévères, par ex. une eau très calcaire
ou une forte présence de mucus, nous conseillons
des nettoyages plus fréquents.
Démontez le corps d'aspiration (1).
Retirez le verrouillage de la chambre de turbine en
tournant dans le sens antihoraire (2).
Déposez le couvercle de turbine (3) et retirez
l'entraînement (4).
Si l'entraînement devait être bloqué en raison d'une
calcification ou d'impuretés sèches : ne pas forcer!
Immergez la pompe ou l'entraînement de pompe
durant env. 24 heures dans une solution à base de
vinaigre.