5. Maintenance and inspection

5.1 Maintenance

Check the water inlet and drainage often. The water and air inflow into the system should be sufficient
so that its performance and reliability does not get compromised. You should clean the pool filter
regularly to avoid damage to the unit caused by clogging of the filter.
The area around the unit should be spacious and well ventilated. Clean the sides of the heat pump
regularly to maintain good heat exchange and to save energy.
Check if all processes in the unit are operational and pay special attention to the operation perssure of
the refrigerant system.
Check the power supply and cable connections regularly. Should the unit begin to function abnormally
or should you notice a smell from an electrical component, arrange fro timely repair or replacement.
You should also purge the water if the unit will not work for an extended period of time. You should
check all parts of the unit thoroughly and completely fill the system with water before turning it on
again afterwards.

5.2 Trouble shooting guide

Improper installation may result in an electrical discharge that could lead to death of-or serious injury
to-pool users, installers or others due to electrical shock and may also cause damage to property.
DO NOT
attempt to modify the internal configuration of the heat pump.
1. Keep your hands and hair clear of the fan blades to avoid injury.
2. If you are not familiar with your pool filtering systems and heat pump:
a.
Do not
attempt to adjust or service without consulting your dealer or your professional pool or air
conditioning contractor.
b.Read the entire installation and user manual before attempting to use, service or adjust the unit.
C.Start the heat pump at least 24 hours after its installation in order to prevent damage to the compressor.
Note: Switch off the power prior to maintenance or repairs .
IMPORTANT REMARK: if a malfunction can not be resolved immediately, in order to analyse the
problem itself we will need to know the message(error code) that is displayed on the controller, as
,
well as the values for the settings (parameter 00-10 for LCD display while parameter 0-A for LED
display) and for status of the heat pump (ambient temperature water inlet outlet temperature
and system coil temperature) just before the failure or, if this is impossible, just after it.
Please keep this information at hand when calling customer service.
On the following pages, you will find an overview of the different types of failure problems that can occur,
along with directions to solve them.
,
17
/